2010
DOI: 10.1590/s0103-50532010000400007
|View full text |Cite
|
Sign up to set email alerts
|

Direct determination of lanthanides in environmental samples using ultrasonic nebulization and ICP OES

Abstract: Baixas concentrações dos catorze elementos de ocorrência natural da série lantanídeos foram diretamente determinadas por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Avaliaram-se interferências espectrais e linhas espectrais mais adequadas foram selecionadas. Os desempenhos da nebulização pneumática e ultra-sônica foram comparados com respeito aos limites de detecção, para ambas as posições de observação do plasma, radial e axial. A influência da potência de radiofrequência sob… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
20
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 25 publications
(20 citation statements)
references
References 22 publications
(38 reference statements)
0
20
0
Order By: Relevance
“…Many methanotrophs, including M. buryatense isolates, have been isolated from sediment samples. In freshwater sediment samples collected from standard sediment collections, lanthanum concentrations have been reported to be around 42 g lanthanum per g sediment (38). Lanthanum is largely insoluble under most environmental conditions; however, the sedimentary lanthanum concentrations found are approximately 300 times the concentration of lanthanum shown to inhibit P mxaF transcription (0.14 g lanthanum per g cultivation medium) (Fig.…”
Section: Discussionmentioning
confidence: 97%
See 1 more Smart Citation
“…Many methanotrophs, including M. buryatense isolates, have been isolated from sediment samples. In freshwater sediment samples collected from standard sediment collections, lanthanum concentrations have been reported to be around 42 g lanthanum per g sediment (38). Lanthanum is largely insoluble under most environmental conditions; however, the sedimentary lanthanum concentrations found are approximately 300 times the concentration of lanthanum shown to inhibit P mxaF transcription (0.14 g lanthanum per g cultivation medium) (Fig.…”
Section: Discussionmentioning
confidence: 97%
“…The decrease of 3 to 4 orders of magnitude in mxa expression by lanthanides in the presence of calcium suggests that XoxF may be the dominant MDH in environmental settings, where lanthanides are relatively abundant (26,27,38). To test this hypothesis in a laboratory setting, an xylE reporter gene was fused to the promoter of mxaF to create an M. buryatense 5GB1C strain with P mxaF -xylE integrated into the chromosome at a region known to be transcriptionally silent (4).…”
Section: Lanthanides Mediate the Mdh Switch In M Buryatense 5gb1cmentioning
confidence: 99%
“…Next, the samples were quantitatively transferred to polypropylene vials, which were topped up to 50 mL with deionized water. 43,51 For ICP-MS analysis the samples were diluted with a 5% HNO 3 solution (v/v) as needed. Method accuracy was assessed using CRMs and indicated absolute errors (in three determinations) lower than 10% (for elements with certified values) and recoveries within the acceptable measurement range, demonstrating that the above method can be extended to samples with similar frameworks (see Supplementary Information section for more details of these results).…”
Section: Ash and Zeolite Characterizationmentioning
confidence: 99%
“…Argon from White Martins/Praxair (Brazil) was used as plasma gas and auxiliary gas, whereas nitrogen with a purity of 99.996% (from White Martins/Praxair) was used as the purging gas. 27 A high efficiency nebulizer ESI APEX-Q (ESI, Omaha, NE) was used for sample introduction into the ICP. The sample was introduced through a PFA microconcentric nebulizer fitted to a cyclonic spray chamber heated at 140 C. The aerosol was then transported to a Peltier-cooled multipass condenser where the temperature was À3 C. The instrumental conditions used are summarized in Table 1.…”
Section: Experimental Part 21 Instrumentationmentioning
confidence: 99%