Direct competitive ELISA for the determination of polychlorinated biphenyls in soil samples

Abstract: A direct competitive ELISA for determination of polychlorinated biphenyls (PCB) in soil samples was described. The standard calibration curve based on Delor 103 (Aroclor 1242) was constructed in the dynamic range of 10-1000 micro g L(-1) and a detection limit of 5.0-12.9 micro g L(-1) (or 0.5-1.29 micro g g(-1) soil) was achieved. When spiked soil samples were extracted with methanol recoveries were 90.6-106.3 %. The effect of methanol and DMSO on assay signal and sensitivity was established. Eight PCB-contami… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2004
2004
2012
2012

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 34 publications
(17 citation statements)
references
References 17 publications
0
17
0
Order By: Relevance
“…However, chromatographic methods could not reach the trace levels in the waters without enrichment step and most of them have drawbacks such as long performing time, tedious sample preparation and expensive instrument. Immunochemical techniques, especially enzyme-linked immunosorbent assay (ELISA), with the features of high sensitivity and specificity, inexpensive instrumentation, simple sample preparation, small sample volumes and rapid analysis have been widely used in environmental analysis [15][16][17][18].…”
Section: Introductionmentioning
confidence: 99%
“…However, chromatographic methods could not reach the trace levels in the waters without enrichment step and most of them have drawbacks such as long performing time, tedious sample preparation and expensive instrument. Immunochemical techniques, especially enzyme-linked immunosorbent assay (ELISA), with the features of high sensitivity and specificity, inexpensive instrumentation, simple sample preparation, small sample volumes and rapid analysis have been widely used in environmental analysis [15][16][17][18].…”
Section: Introductionmentioning
confidence: 99%
“…This is based on the value of the dependent variable for that sample, which is a measured response from an instrument. Calibration curves are produced using standards whose values for the independent variable are known accurately and precisely [27,28,29,30]. Examples of such standards are certified reference materials (CRMs), whose values are certified by a procedure, and are given with an associated uncertainty.…”
Section: Resultsmentioning
confidence: 99%
“…In the early days, soil and sediment samples were easily extracted by shaking with methanol or/and Soxhlet [47,54,55] or using an ultrasonic process [56], but these methods did not result in a complete extraction, leading to compound loss or the need for further cleanup. In order to solve these problems, several alternative extraction technologies were introduced, which resulted in time and reagent savings.…”
Section: Detection Methodsmentioning
confidence: 99%
“…Tsutsumi et al [73] cleaned up sample extracts from retail fish contaminated by dioxin-like PCBs by passing them through a multi-layer silica gel column and an alumina column, resulting in eluents suitable for ELISA assays. Deng et al [55] cleaned soil and sediment samples on a column containing activated Florisil [74]. Nichkova et al [56] utilized a multilayered silica gel column and an activated carbon column to clean up extracted sediment samples contaminated by PCDD/Fs.…”
Section: Detection Methodsmentioning
confidence: 99%
See 1 more Smart Citation