2016
DOI: 10.1007/s12161-016-0600-9
|View full text |Cite
|
Sign up to set email alerts
|

Direct and Simultaneous Determination of Copper and Iron in Flours by Solid Sample Analysis and High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 31 publications
0
4
0
Order By: Relevance
“…The regression curves of individual Cu(II), Fe(III), and Ni(II) at 805 nm, 295 nm, and 395 nm as a function of concentration, were shown in Figure 2. The concentration required to obtain a linear curve for Cu(II), Fe(III), and Ni(II) salts was higher than their complex form [2][3][4][5]. But, in terms of sample preparation direct Cu(II), Fe(III), and Ni(II) salts were simpler and did not require a buffer solution.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The regression curves of individual Cu(II), Fe(III), and Ni(II) at 805 nm, 295 nm, and 395 nm as a function of concentration, were shown in Figure 2. The concentration required to obtain a linear curve for Cu(II), Fe(III), and Ni(II) salts was higher than their complex form [2][3][4][5]. But, in terms of sample preparation direct Cu(II), Fe(III), and Ni(II) salts were simpler and did not require a buffer solution.…”
Section: Resultsmentioning
confidence: 99%
“…Various spectrophotometric methods, such as atomic absorption spectroscopy (AAS) [5], atomic fluorescence spectroscopy (AFS) [6], and UV-Vis spectrophotometry [7], as well as other analytical techniques, have been used to quantitatively analyze mixed metal ion samples. Among these methods, UV-Vis spectrophotometry is one of the most extensively employed techniques, and…”
Section: Introductionmentioning
confidence: 99%
“…The iron content was read using standard solutions of Iron (III) nitrate. Adsorption of 0.5, 1, 1.5, and 2 mg/L standard solutions were read at the wavelength of 248.3 nm and then the sample absorbance was read [ 22 , 23 , 24 ].…”
Section: Methodsmentioning
confidence: 99%
“…16 A very important feature of this instrument is that it can perform simultaneous or sequential multi-element analysis (Tables 2 and 3). The HR-CS-GFAAS technique was mainly applied for the simultaneous or sequential multi-element analysis of foodstuffs, 82,87,109,123,125,92,93,99,[102][103][104]106,108 environmental media, 79,82,111,112,117,122,85,86,90,94,96,100,108,110 crude oil [75][76][77] and biological specimens. 80,107 Twenty-eight elements were determined by this technique and Fe, Ni, Cd and Co were the most frequently examined.…”
Section: Simultaneous or Sequential Multi-element Analysis By Hr-cs-gfaasmentioning
confidence: 99%