2010
DOI: 10.1016/j.agrformet.2010.01.016
|View full text |Cite
|
Sign up to set email alerts
|

Direct advection measurements do not help to solve the night-time CO2 closure problem: Evidence from three different forests

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
116
0
5

Year Published

2010
2010
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 137 publications
(126 citation statements)
references
References 46 publications
5
116
0
5
Order By: Relevance
“…In fact, wind measurements inside the canopy can be severely influenced by very local conditions, limiting their spatial representativeness. Furthermore, as stated by Aubinet et al (2010), the spatial resolution of the CO 2 measurement system as well was not sufficient to take small-scale field heterogeneities into account. Therefore, major uncertainties can be attributed to under-representativeness of the samplings.…”
Section: Resultsmentioning
confidence: 99%
“…In fact, wind measurements inside the canopy can be severely influenced by very local conditions, limiting their spatial representativeness. Furthermore, as stated by Aubinet et al (2010), the spatial resolution of the CO 2 measurement system as well was not sufficient to take small-scale field heterogeneities into account. Therefore, major uncertainties can be attributed to under-representativeness of the samplings.…”
Section: Resultsmentioning
confidence: 99%
“…However, the accuracy of EC measurements of NEE has been questioned particularly over tall vegetation in complex terrains [2][3][4][5][6][7] and even over various forests with relative flat terrains [7,8]. One of the key factors that results in uncertainties in measuring scalar exchanges between the atmosphere and forests is the complexity of airflow above and within the forest canopy [4,[9][10][11].…”
Section: Introductionmentioning
confidence: 99%
“…7;Aubinet et al, 2012, р. 400-401] на протяжении последних лет существует консенсус относительно высокого качества оценок метода микровихревых пульсаций, хотя и отмечаются проблемы, связанные с измерением потоков ночью, крупномасштабными вихрями и незамкнутостью теплового баланса [Finnigan, 2008;Aubinet et al, 2010]. Для доказательства вышеупомянутого вывода диссертанту необходимо было провести оценку того, насколько точно измеряемые камерным методом величины УП метана позволяют оценивать эмиссию метана из экосистем на масштабе, на котором работает метод микровихревых пульсаций и показать, что эта оценка точнее, чем даваемая методом микровихревых пульсаций.…”
Section: используемые сокращенияunclassified