2015
DOI: 10.1016/j.optcom.2014.10.035
|View full text |Cite
|
Sign up to set email alerts
|

Digital holographic microscopy for microalgae biovolume assessment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…The utility of DHM for detection of microorganisms (especially in sparse environmental samples) has been demonstrated for numerous applications, such as diagnostics, water quality measurements, and ocean monitoring of microbial populations and behavior [ 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 ]. The technique has also been used to investigate the basic biophysics of microbial motility [ 35 , 36 , 37 , 38 , 39 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The utility of DHM for detection of microorganisms (especially in sparse environmental samples) has been demonstrated for numerous applications, such as diagnostics, water quality measurements, and ocean monitoring of microbial populations and behavior [ 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 ]. The technique has also been used to investigate the basic biophysics of microbial motility [ 35 , 36 , 37 , 38 , 39 ].…”
Section: Introductionmentioning
confidence: 99%
“…The image stacks can be analyzed for particle positions, and those positions tracked over time to obtain particle trajectories. The utility of DHM for detection of microorganisms (especially in sparse environmental samples) has been demonstrated for numerous applications, such as diagnostics, water quality measurements, and ocean monitoring of microbial populations and behavior [27][28][29][30][31][32][33][34]. The technique has also been used to investigate the basic biophysics of microbial motility [35][36][37][38][39].…”
Section: Introductionmentioning
confidence: 99%
“…These perturbations may vary in an unpredictable way from one acquisition to another because they depend on random external conditions, which are difficult to control. Since in many DHM applications accurate phase values must be extracted from the quantitative phase map [11], this aberration must be compensated in order to have access to reliable local information of the integrated optical path length (OPL) which can be used to measure either the integral refractive index or the topography of the object under study.…”
Section: Introductionmentioning
confidence: 99%