Differential chemical imaging of extracellular acidification within microfluidic channels using a plasma-functionalized light-addressable potentiometric sensor (LAPS)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 29 publications
0
6
0
Order By: Relevance
“…Can be used as imaging devices allowing to visualize the ion concentration as a two-dimensional map [198] Potentiometric sensor pH is determined from the voltage measured between a reference electrode and a sensitive electrode obtained exploiting metal oxides sensitivity to H+…”
Section: Light Addressable Potentiometric Sensor (Laps)mentioning
confidence: 99%
See 1 more Smart Citation
“…Can be used as imaging devices allowing to visualize the ion concentration as a two-dimensional map [198] Potentiometric sensor pH is determined from the voltage measured between a reference electrode and a sensitive electrode obtained exploiting metal oxides sensitivity to H+…”
Section: Light Addressable Potentiometric Sensor (Laps)mentioning
confidence: 99%
“…Indeed, these sensors have been used in microfluidic systems: LAPS integrated with a PDMS chamber have been used for real-time pH monitoring of the medium where hepatoma HepG2 cells were cultured and treated with doxorubicin in order to assess the extracellular acidification rate [ 209 ]; and, in a microphysiometer for pH monitoring to track the metabolism of human breast cancer cells [ 210 ]. Furthermore, by cultivating adherent CHO-K1 on the LAPS surface, it was possible to image the extracellular acidification [ 198 ]. The cell’s environment’s pH can be controlled through potentiometric measures by placing the electrodes in a microfluidic device [ 211 ].…”
Section: Advantages Of Microfluidic-chip Technology For Evolving Cmentioning
confidence: 99%
“…Before seeding the cells, the microfluidic channels were sterilized by flushing them with 70% ethanol for one hour. Cell culturing was performed as mentioned in the literature [11]. 40000 cells/cm 2 were seeded into each channel.…”
Section: Cell Culturing and Cryopreservationmentioning
confidence: 99%
“…This way, the chip was connected to the self-developed LAPS measurement set-up. Extracellular acidification of the cells was monitored as previously reported in the literature [11,18].…”
Section: Sensor Signal Measurement After Cryopreservationmentioning
confidence: 99%
See 1 more Smart Citation