2016
DOI: 10.1016/j.spinee.2015.11.034
|View full text |Cite
|
Sign up to set email alerts
|

Differences in bone mineral density of fixation points between lumbar cortical and traditional pedicle screws

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
35
0
12

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 51 publications
(47 citation statements)
references
References 28 publications
0
35
0
12
Order By: Relevance
“…This may prevent complications and facilitate postoperative relief for certain spinal geometric distortions and deformities. Thus, during the last decade, vertebral augmentation with cement, kyphoplasty and vertebroplasty [23,24], in conjunction with pedicle screwbased approaches [25][26][27] have been used for treating severe spinal deformities.…”
Section: Discussionmentioning
confidence: 99%
“…This may prevent complications and facilitate postoperative relief for certain spinal geometric distortions and deformities. Thus, during the last decade, vertebral augmentation with cement, kyphoplasty and vertebroplasty [23,24], in conjunction with pedicle screwbased approaches [25][26][27] have been used for treating severe spinal deformities.…”
Section: Discussionmentioning
confidence: 99%
“…In this study, we used clinical data from DXA and CT to define the regional bone qualities (cHU, mHU, lUH, fHU, and pHU) considering various conditions of general bone qualities (BMD). DXA is a useful tool for assessing general bone quality due to its convenience, while HU values obtained from CT are strong indicators for evaluating regional bone quality, so these two tools have been used to determine general and local bone quality . However, there are other factors that influence the real strength of bone (such as structural factors and vector of force), and the HU value is not a direct reflection of the strength of bone; therefore, mechanical tests should be conducted to minimize bias and present the real strength data …”
Section: Discussionmentioning
confidence: 99%
“…CT analyses demonstrated that Hounsfield units along CBT, even with shorter and smaller bone paths, were four times higher than those along TT 13) , and this tendency was prominent with increasing generation 14) . Theoretically, CBT can achieve a 4-point cortical contact between the dorsal starting point, inferomedial pedicle wall, anterolateral pedicle wall, and lateral curvature of the vertebral endplate ( Fig.…”
Section: Anatomical Characteristicsmentioning
confidence: 93%