Diagnostics of inter-turn short-circuit in the stator winding of the induction motor

Abstract: A stator malfunction occurs due to insulation damage, which means that the stator is directly connected to the power supply, and a direct connection is the direct cause of a major accident. For this reason, a lot of research is being done to identify faults. In recent years, studies on Motor Electrical Signature Analysis are being performed, sensorless methods for fault diagnosis of the stator of an induction motor. However, it has problems with it, it has the difficulty in interpreting multi-faults and in det… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 7 publications
0
2
0
Order By: Relevance
“…The effect of distributed generation on short-circuit currents depends on the type of generator and how it is connected to the power grid (directly or initially converted using an inverter [24,25]. In the case of rotating generators directly connected to the grid (3), the generator impedance Z dg = R + jX in short-circuit mode can be determined as follows [26,27]:…”
Section: Decreased Sensitivity Of Protectionmentioning
confidence: 99%
“…The effect of distributed generation on short-circuit currents depends on the type of generator and how it is connected to the power grid (directly or initially converted using an inverter [24,25]. In the case of rotating generators directly connected to the grid (3), the generator impedance Z dg = R + jX in short-circuit mode can be determined as follows [26,27]:…”
Section: Decreased Sensitivity Of Protectionmentioning
confidence: 99%
“…Thus, electric motors with parameters which meets the following requirements, can be used for operation as part of in-wheel motor: high torque at low speeds; wide speed control range; high coefficient of power density. Electric motors which corresponds to mentioned above criteria are presented by the following types: asynchronous electric motor [4,5], permanent magnet synchronous motor [6,7]; brushless DC motor [8]; reluctance motor [9]. Based on the comparative analysis carried out in work [10], the permanent magnet synchronous motor (PMSM) is the most suitable type of electric motor forin-wheel motors.…”
Section: Introductionmentioning
confidence: 99%