2019
DOI: 10.1016/j.arbr.2018.11.007
|View full text |Cite
|
Sign up to set email alerts
|

Diagnostic Accuracy of Pleural Fluid Adenosine Deaminase for Diagnosing Tuberculosis. Meta-analysis of Spanish Studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 27 publications
(20 citation statements)
references
References 29 publications
0
19
1
Order By: Relevance
“… * Information from references 4 , 10 , 12 , 25 , 28 , 31 , 38 , 40 , 44 , 52 and 53 . $ For labeling mesothelioma.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“… * Information from references 4 , 10 , 12 , 25 , 28 , 31 , 38 , 40 , 44 , 52 and 53 . $ For labeling mesothelioma.…”
Section: Discussionmentioning
confidence: 99%
“…A recent meta-analysis of 16 Spanish studies, totaling 4147 patients, showed that PF ADA had 93% sensitivity, 92% specificity, LR positive of 12, LR negative of 0.08, and AUC of 0.968 for identifying TB effusions. 28 The high diagnostic accuracy of ADA was independent of the technique used for its measurement, whether colorimetric Giusti, manual or automated kinetic methods. The commonly accepted ADA diagnostic cutoff is >35 U/l.…”
Section: Biomarkers Of Pleural Tuberculosismentioning
confidence: 99%
“…4,5 As a nonspecific indicator of cellular immunity, altered ADA activity has been detected in many diseases, including tuberculosis, rheumatoid arthritis, systemic lupus erythematosus, and liver diseases. 68…”
Section: Introductionmentioning
confidence: 99%
“…The data from a total of 86 studies eligible for evaluation, including 5 studies from Turkey [13][14][15][16][17] were evaluated in five different meta-analyses. 11,[18][19][20][21] All of these meta-analyses showed that PE ADA activity had a high value diagnostically. A recent meta-analysis of 16 Spanish studies, totaling 4,147 patients, showed that PE ADA had 93% sensitivity, 92% specificity, positive likelihood ratio (LR) of 12, negative LR of 0.08, and area under the curve (AUC) of 0.968 for identifying TPE.…”
Section: Adenosine Deaminasementioning
confidence: 99%
“…The ADA cutoff point for the diagnosis of TPE most widely used was 40 U/L. 21 There is large increase (positive LR: 12) in the probability of TPE with an ADA >40 U/L and large increase (negative LR: 0.08) in the probability of non-TPE (another cause of exudative PE) with an ADA <40 U/L. In other words, an ADA >40 U/L is a high diagnostic accuracy for identifying TPE.…”
Section: Adenosine Deaminasementioning
confidence: 99%