1996
DOI: 10.2214/ajr.166.4.8610560
|View full text |Cite
|
Sign up to set email alerts
|

Diagnosis of renovascular hypertension: feasibility of captopril-sensitized dynamic MR imaging and comparison with captopril scintigraphy.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
23
0

Year Published

2000
2000
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 56 publications
(24 citation statements)
references
References 10 publications
(4 reference statements)
1
23
0
Order By: Relevance
“…While common clinical protocols call for injection of 5-20 mmol of DTPA (15,16), the relationship between the dose of the tracer and the accuracy of subsequent measurements has not been systematically analyzed. Our results suggest the feasibility of MR measurements using doses of Gd-DTPA that are several times lower than current standards.…”
Section: Discussionmentioning
confidence: 99%
“…While common clinical protocols call for injection of 5-20 mmol of DTPA (15,16), the relationship between the dose of the tracer and the accuracy of subsequent measurements has not been systematically analyzed. Our results suggest the feasibility of MR measurements using doses of Gd-DTPA that are several times lower than current standards.…”
Section: Discussionmentioning
confidence: 99%
“…Preliminary feasibility has been reported both in animal models (Fig. 4) (114) and in human subjects (44).…”
Section: K(t)] Is Given Bymentioning
confidence: 95%
“…A physiological imaging diagnosis of renal artery stenosis is currently made using angiotensin-converting enzyme inhibitor (ACE-I) renal scintigraphy and is arguably a good predictor of response to therapy (16,39). The signal intensity-time curves obtained with predominantly T 1 -weighted sequences (such as those used for acquiring contrast-enhanced MR angiography) can be used in concert with ACE inhibition to differentiate kidneys supplied by stenotic renal arteries (44,114).…”
Section: K(t)] Is Given Bymentioning
confidence: 99%
“…A significant linear correlation was found between extraction fraction measured with MRI vs. inulin [11]. Grenier et al [12] studied 15 hypertensive patients with renal artery stenosis and found that captopril-sensitized dynamic MRI of the kidney with a Gd3 + chelate was feasible in patients with renovascular hypertension. There was a good correlation between MR and nuclear renography, although captopril-induced changes were not seen in all patients shown to have the disease.…”
Section: Dynamic Serial Gadolinium-enhanced Mrimentioning
confidence: 99%