2007
DOI: 10.1253/circj.71.122
|View full text |Cite
|
Sign up to set email alerts
|

Diagnosis of Left Atrial Appendage Thrombi by Multiplane Transesophageal Echocardiography Interlaboratory Comparative Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
14
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(16 citation statements)
references
References 25 publications
2
14
0
Order By: Relevance
“…Recent studies have reported that the accuracy, 5 interobserver reproducibility, 6 and level of diagnostic confidence 7 associated with evaluation of the LAA for thrombi by 2D TEE are suboptimal. Schneider et al 6 evaluated interlaboratory variability for the diagnosis of LAA thrombi in 50 patients with atrial fibrillation and found that the interpretations of 2 expert observers from 2 different laboratories were discordant in 11 (22%) of the TEE studies.…”
Section: Discussionmentioning
confidence: 99%
“…Recent studies have reported that the accuracy, 5 interobserver reproducibility, 6 and level of diagnostic confidence 7 associated with evaluation of the LAA for thrombi by 2D TEE are suboptimal. Schneider et al 6 evaluated interlaboratory variability for the diagnosis of LAA thrombi in 50 patients with atrial fibrillation and found that the interpretations of 2 expert observers from 2 different laboratories were discordant in 11 (22%) of the TEE studies.…”
Section: Discussionmentioning
confidence: 99%
“…8 This is exemplified in multiple case reports, which describe patients undergoing unnecessary sternotomies due to misinterpretation of aortic dissection on echocardiography. 11,12 Moreover, even with multiplane echocardiography, these artifacts significantly increase inter-observer variability in the diagnosis of LAAT. Echocardiography is the method of choice for evaluation of LAAT.…”
Section: Examples Of Simple Reverberation Artifactsmentioning
confidence: 99%
“…9,10 Simple reverberation artifacts are also clinically significant in diagnosing left atrial appendage thrombi (LAAT). 12 If this artifact is not recognized, patients can end up receiving undue anticoagulation therapy or even undue surgery. However, multiple studies have recognized that a significant portion of cases contained reverberation artifacts that were misinterpreted as thrombi.…”
Section: Examples Of Simple Reverberation Artifactsmentioning
confidence: 99%
See 1 more Smart Citation
“…Although tranesophageal echocardiography remains the gold standard for the detection of intraatrial thrombi, interobserver variability remains 1 . In one study, in which intraatrial thrombi on transesophageal echocardiography were classified by experienced echocardiographers as definite, questionable, or absent, there was significant interobserver variability with a different conclusion in 11 of 50 cases (κ= 0.5) 2 . Echocontrast has been demonstrated to be useful in differentiating intraatrial smoke from intraatrial thrombus, but not in the case of a pericardial effusion surrounding the left atrium 3 …”
mentioning
confidence: 99%