2016
DOI: 10.1109/tvlsi.2015.2439698
|View full text |Cite
|
Sign up to set email alerts
|

DFSB-Based Thermal Management Scheme for 3-D NoC-Bus Architectures

Abstract: Three-dimensional network-on-chip (NoC)-bus hybrid architectures are motivated to achieve lower propagation latency and higher bandwidth in vertical direction, by taking the advantage of the short interwafer distances in 3-D integrated circuits. However, 3-D integration technology increases the power density of the chip, and thus, results in thermalrelated problems. Therefore, to ensure that the chip operates within the safe temperature range, while keeping the traffic performance undegraded, this paper propos… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 36 publications
0
5
0
Order By: Relevance
“…Several works have used trace-based evaluation for core thermal management policies [16,17,34,60]. Cox et al [16] use trace-based HotSpot simulation to obtain temperature and perform a thermal-aware mapping of streaming applications on 3D processors.…”
Section: Background and Related Workmentioning
confidence: 99%
“…Several works have used trace-based evaluation for core thermal management policies [16,17,34,60]. Cox et al [16] use trace-based HotSpot simulation to obtain temperature and perform a thermal-aware mapping of streaming applications on 3D processors.…”
Section: Background and Related Workmentioning
confidence: 99%
“…However, compression ratio using this technique is very low. In [22], a 3-D NoC-bus hybrid architecture presented to make routing more efficient in bus architectures of VLSI design through 3-D IC technology hence the power consumption and this system also reduces the computational cost. However, due to high interconnect traffic the thermal issues can degrade performance of the system.…”
Section: Related Workmentioning
confidence: 99%
“…Meng [4] presented a novel optimized policy to choose voltage-frequency settings for the execution mode of each core by utilizing predictions on a regression model while maintaining power and temperature constraints. Our prior work [5] presented a thermal-aware policy of dynamic frequency scaling bus (DFSB) for 3D Network-on-Chip (NoC) hybrid architectures. However, the DVFS-based thermal management system is an open-loop control system that requires accurate power measurement and limits the stability of the system.…”
Section: Introductionmentioning
confidence: 99%