2000
DOI: 10.1111/j.1540-8159.2000.tb00847.x
|View full text |Cite
|
Sign up to set email alerts
|

Device Follow‐up in the Age of Automaticity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2002
2002
2014
2014

Publication Types

Select...
4
3
1

Relationship

3
5

Authors

Journals

citations
Cited by 24 publications
(18 citation statements)
references
References 14 publications
0
18
0
Order By: Relevance
“…Manufacturers' guidelines for device follow-up may vary with individual models and should be available. Device automaticity has facilitated follow-up, 316 as has the implementation of remote monitoring techniques. 513,517 Depending on the manufacturer, remote device interrogation is achieved through Internet-based systems or via radiofrequency transmissions from the ICD via a phone device to a central monitoring center; remote reprogramming of devices is not available currently.…”
Section: Elements Of Implantable Cardioverter-defibrillator Follow-upmentioning
confidence: 99%
See 1 more Smart Citation
“…Manufacturers' guidelines for device follow-up may vary with individual models and should be available. Device automaticity has facilitated follow-up, 316 as has the implementation of remote monitoring techniques. 513,517 Depending on the manufacturer, remote device interrogation is achieved through Internet-based systems or via radiofrequency transmissions from the ICD via a phone device to a central monitoring center; remote reprogramming of devices is not available currently.…”
Section: Elements Of Implantable Cardioverter-defibrillator Follow-upmentioning
confidence: 99%
“…Automatic features, such as automatic threshold assessment, have been incorporated increasingly into newer devices and facilitate follow-up for patients who live far from follow-up clinics. 316 However, these automatic functions are not universal and need not and cannot supplant the benefits of direct patient contact, particularly with regard to history taking and physical examination.…”
Section: Pacemaker Follow-upmentioning
confidence: 99%
“…Automaticity in devices, such as automatic threshold assessment, may alert the physician to the need for intensified follow-up and device adjustments and may reduce the frequency or duration of office visits. It cannot, however, supplant direct patient/pacemaker evaluation (9).…”
Section: See Page 2012mentioning
confidence: 99%
“…The technology has shown that there is a relatively long trouble-free period in the midst of a device's life; most issues arise early after implantation (wound healing, threshold changes) or toward the device's end of life. 30 These lessons have been applied increasingly to the management of ICDs; depending on the manufacturer, remote monitoring may be enabled through Internet-based systems or through radiofrequency transmission from a transmitter in the ICD via a phone device to a service center. Nonetheless, there is no substitute for direct patient contact, with an essential role for the physician to uncover device-related issues.…”
Section: Follow-up Of the Patient After Device Implantationmentioning
confidence: 99%
“…The latter may be defined as the automatic regulation of device function by programmed algorithms (see below) that are based on patient conditions and pacemaker/ICD system conditions, without the need for clinician input. 30 Transtelephonic monitoring of pacemakers has been available for nearly 3 decades. The technology has shown that there is a relatively long trouble-free period in the midst of a device's life; most issues arise early after implantation (wound healing, threshold changes) or toward the device's end of life.…”
Section: Follow-up Of the Patient After Device Implantationmentioning
confidence: 99%