2011
DOI: 10.1016/j.jnoncrysol.2010.10.046
|View full text |Cite
|
Sign up to set email alerts
|

Development of thermally stable tellurite glasses designed for fabrication of microstructured optical fibers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
27
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
4
3
2

Relationship

3
6

Authors

Journals

citations
Cited by 52 publications
(28 citation statements)
references
References 19 publications
1
27
0
Order By: Relevance
“…Thus, OCT has been initially developed for ophthalmology [1], and it is usually focused on biomedical applications, including in skin, dentistry, or endoscopy [24]. For non-medical applications, OCT has been used especially for in-depth investigations of non-metallic (i.e., non-reflective) samples, in Non-Destructive Testing (NDT) of plastics and composites [25,26], electronic materials [27,28], dental materials [21,29,30], glass [31,32], or even art works like paintings [33]-to determine their internal structure, matrices and reinforcement, superficial stress, layer thickness, defects occurring inside layers.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, OCT has been initially developed for ophthalmology [1], and it is usually focused on biomedical applications, including in skin, dentistry, or endoscopy [24]. For non-medical applications, OCT has been used especially for in-depth investigations of non-metallic (i.e., non-reflective) samples, in Non-Destructive Testing (NDT) of plastics and composites [25,26], electronic materials [27,28], dental materials [21,29,30], glass [31,32], or even art works like paintings [33]-to determine their internal structure, matrices and reinforcement, superficial stress, layer thickness, defects occurring inside layers.…”
Section: Introductionmentioning
confidence: 99%
“…For those reasons, relaxation frequencies are set non-zero but small enough (v c1,2,3 = 10 −4 f p1,2,3 ) to assure that the loss factor is negligible. Table 1 shows Sellmeier coefficients and the corresponding Lorentz parameters of two glasses, namely TWNN16 and PBS517 (Stępień et al 2011). Once the material properties are properly represented, total fiber dispersion can be determined.…”
Section: Electromagnetic Analysis Of Pcfmentioning
confidence: 99%
“…For the initial experiments in this work, we selected glasses known for their appreciable transmission characteristics in the visible and mid-infrared parts of spectrum ( Fig. 2) (Stepien et al 2011;Lorenc et al 2008). The composition of the selected glasses is shown in Table 1.…”
Section: Hot Embossing Glass and Materials For Stamp Selectionmentioning
confidence: 99%