2013
DOI: 10.1070/qe2013v043n02abeh015045
|View full text |Cite
|
Sign up to set email alerts
|

Development of precision laser goniometer systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(11 citation statements)
references
References 8 publications
0
11
0
Order By: Relevance
“…Curve 3 defines the systematic error of the optical encoder calculated by the Formula (13). The discrepancy between curves 1 and 2 is caused by a systematic error of ring laser, which can be found according to expression (12). Note that the amplitude of the systematic error of the ring laser at a constant external magnetic field depends on the rotation rate.…”
Section: Results Of Optical Encoder Calibration In the "On-axis" Modementioning
confidence: 94%
See 1 more Smart Citation
“…Curve 3 defines the systematic error of the optical encoder calculated by the Formula (13). The discrepancy between curves 1 and 2 is caused by a systematic error of ring laser, which can be found according to expression (12). Note that the amplitude of the systematic error of the ring laser at a constant external magnetic field depends on the rotation rate.…”
Section: Results Of Optical Encoder Calibration In the "On-axis" Modementioning
confidence: 94%
“…The main uncertainty of the LDG is due to the influence of an external magnetic field on the ring laser scale. The laser gyro has an axis of sensitivity to the magnetic field lying in the plane of the ring laser resonator [12]. During rotation, the sensitivity axis changes its orientation relative to the magnetic field lines of force, which leads to a systematic error at the first harmonic of the rotation frequency, provided that the magnetic field is uniform and constant.…”
Section: Reversal Methodsmentioning
confidence: 99%
“…Its typical resolution is limited to 0.1" (0.5 μrad) by the influence of the environmental parameters on the ring laser dynamics (birifrangency induced by spurious magnetic fields on the corner prisms, mechanical instabilities of the rotator, non-optimization of the geometrical parameters of the laser cavity). The resolution of the prototype active in St. Petersburg has been pushed down to 100 nrad through a careful (and quite cumbersome) analysis of all these systematic errors [10].…”
Section: Accuracy Of Rl Goniometermentioning
confidence: 99%
“…The dynamic laser goniometer systems, 1 the scale of which is produced by the ring laser or an optical angle encoder (OAE), can be successfully used for calibration of the angle encoders, which are characterized by high accuracy and high speed of operation.…”
Section: Introductionmentioning
confidence: 99%
“…The dynamic laser goniometer systems, 1 the scale of which is produced by the ring laser, can be successfully used for calibration of the angle encoders. The ring laser operating in the mode of the angle measurement during its rotation has a number of undeniable advantages, such as high degree of uniformity and potential accuracy.…”
Section: Introductionmentioning
confidence: 99%