Arsenic Contamination of Groundwater 2008
DOI: 10.1002/9780470371046.ch7
|View full text |Cite
|
Sign up to set email alerts
|

Development of Measurement Technologies for Low‐Cost, Reliable, Rapid, On‐Site Determination of Arsenic Compounds in Water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 57 publications
0
3
0
Order By: Relevance
“…The need for test methods that facilitate extensive and continuous As monitoring by local people was soon understood when the problem became known; the use of laboratory-based tests had to be excluded because of their costs and the logistics involved in sampling, transport and communicating results. Many studies have been published over the last 15 years either describing new field kits or comparing existing ones ( [64] and references therein). The ideal test should be affordable, robust, mobile, safe for the user, environmentally friendly, and easy to operate.…”
Section: Cheap Simple and Reliable Analytical Methodsmentioning
confidence: 99%
“…The need for test methods that facilitate extensive and continuous As monitoring by local people was soon understood when the problem became known; the use of laboratory-based tests had to be excluded because of their costs and the logistics involved in sampling, transport and communicating results. Many studies have been published over the last 15 years either describing new field kits or comparing existing ones ( [64] and references therein). The ideal test should be affordable, robust, mobile, safe for the user, environmentally friendly, and easy to operate.…”
Section: Cheap Simple and Reliable Analytical Methodsmentioning
confidence: 99%
“…The time associated with generating arsine gas has been analyzed for a variety of FTKs. Through increasing the time span of the reaction samples of 15 μg/L, those previously analyzed incorrectly were properly registered above a semi-quantitative concentration of 10 μg/L for both the EZ and Hach FTKs [45], [46]. Although the FTK has focused on promoting short reaction times to increase sales, it is apparent that lengthening this reaction will provide a more quantitative result.…”
Section: Generation Of Arsine Gasmentioning
confidence: 97%
“…The status of test kits based on the Gutzeit reaction has been reviewed by Tyson. 12 The US Environmental Protection Agency's Environmental Technology Verification (ETV) Program 13 has, for several years, been evaluating arsenic test kits according to a rigorous and extensive set of standard protocols. The ETV program has, to date, evaluated eight test kits based on the Gutzeit reaction submitted by the manufacturers.…”
Section: Introductionmentioning
confidence: 99%