2019
DOI: 10.1016/j.aca.2019.05.026
|View full text |Cite
|
Sign up to set email alerts
|

Development of luminescent nanoswitch for sensing of alkaline phosphatase in human serum based onAl3+-PPi interaction and Cu NCs with AIE properties

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(8 citation statements)
references
References 55 publications
0
8
0
Order By: Relevance
“…The developed biosensor could operate in a wide linear range (0.5-25 mU/mL) with LOD of 0.15 mU/mL. 224 The opposite effect has been observed when poly(thymine)-CuNCs were applied for the detection of ALP. 262 In brief, the quenching of PL (in the presence of Cr 3+ ions) was restored by the addition of PPi, due to the strong binding affinity of pyrophosphate towards the chromium ions.…”
Section: Alkaline Phosphatase Activity Detectionmentioning
confidence: 99%
See 1 more Smart Citation
“…The developed biosensor could operate in a wide linear range (0.5-25 mU/mL) with LOD of 0.15 mU/mL. 224 The opposite effect has been observed when poly(thymine)-CuNCs were applied for the detection of ALP. 262 In brief, the quenching of PL (in the presence of Cr 3+ ions) was restored by the addition of PPi, due to the strong binding affinity of pyrophosphate towards the chromium ions.…”
Section: Alkaline Phosphatase Activity Detectionmentioning
confidence: 99%
“…74 GSH-CuNCs with Al 3+ -triggered AIE enhancement were also applied for the ALP activity detection. 224 The addition of Al 3+ to the cluster solution caused aggregation and thus, PL enhancement. In the presence of PPi, due to the Al 3+ -PPi complexation, the Pl was quenched.…”
Section: Alkaline Phosphatase Activity Detectionmentioning
confidence: 99%
“…In addition, it was also reported that GSH-CuNCs exhibited a similar performance, which was used for detecting pyrophosphatase and alkaline phosphatase (Geng et al 2019;Ye et al 2019). The difference was that Fe 3+ was replaced by Al 3+ , which could enhance the fluorescence of GSH-CuNCs mainly due to the AIEE effect.…”
Section: Pyrophosphatase Detectionmentioning
confidence: 98%
“…TA-Cu NCs were successfully shown to detect pyrophosphatase in human serum samples with a detection limit of 0.15 U/L. Moreover, glutathione-Cu NCs (GSH-Cu NCs) could exhibit an identical detection chemistry when the Fe 3+ was replaced by Al 3+ [ 102 , 103 ].…”
Section: Copper Nanoclusters (Cu Ncs) In Disease Diagnosis: Biosensor...mentioning
confidence: 99%