2018
DOI: 10.1007/s11356-018-2707-6
|View full text |Cite
|
Sign up to set email alerts
|

Development of immunochromatographic assays for the detection of imidacloprid in soil chemical barrier

Abstract: A soil chemical barrier is the most important and common way to control termites; fast and on-site detection methods are significant tools to verify pesticide content meeting the standard requirements. In this study, conventional and enhanced immunochromatographic assays (ICAs) containing two test lines (TLs) were developed to semi-quantitatively detect imidacloprid in soil chemical barrier, and detection results were quantified by a smart phone. According to the results, the disappearance concentrations of fi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 18 publications
0
4
0
Order By: Relevance
“…The ninety-six-well microplates were purchased from Corning Costar (Corning, NY, USA). The mAb 3D11B12E5 purified by protein A column and phage-displayed cyclic 8, 9, 10-residue random peptide libraries were prepared and stored in our own laboratory [ 13 , 30 ]. The sequencing primer was synthesized by Genscript Bio.…”
Section: Methodsmentioning
confidence: 99%
“…The ninety-six-well microplates were purchased from Corning Costar (Corning, NY, USA). The mAb 3D11B12E5 purified by protein A column and phage-displayed cyclic 8, 9, 10-residue random peptide libraries were prepared and stored in our own laboratory [ 13 , 30 ]. The sequencing primer was synthesized by Genscript Bio.…”
Section: Methodsmentioning
confidence: 99%
“…IMI and its other structural analogs were purchased from Dr. Ehrenstorfer GmbH (Germany). The anti-IMI mAb (3D11B12E5) and IMI hapten were prepared as described previously (Yang et al, 2018). The haptens of ACE and THI were prepared as described previously (Wanatabe et al, 2001;Kim et al, 2003).…”
Section: Reagentsmentioning
confidence: 99%
“…And then, 20 mL of acetonitrile were transferred and evaporated to dryness with a rotary evaporator at 40 • C. The extracts were dissolved with 5 mL of acetonitrile:water (70:30, v/v) and the concentrations of IMI were detected by HPLC with a Eclipse plus C18 column (4.6 mm × 250 mm × 5 µm). A mixture of acetonitrile:water (70:30, v/v) was used as the mobile phase at a flow rate of 1.0 mL/min at 30 • C. The detection wavelength was 270 nm and the injection volume was 20 µl (Yang et al, 2018).…”
Section: Analysis Of Spiked Samplesmentioning
confidence: 99%
See 1 more Smart Citation