2019
DOI: 10.1080/09540105.2018.1551331
|View full text |Cite
|
Sign up to set email alerts
|

Development of ic-ELISA and an immunochromatographic strip assay for the detection of aristolochic acid Ⅰ

Abstract: View related articles View Crossmark data Citing articles: 5 View citing articles Development of ic-ELISA and an immunochromatographic strip assay for the detection of aristolochic acid Ⅰ

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 28 publications
0
9
0
Order By: Relevance
“…This contains target-specific antibody-reporter molecule conjugates. In cases where the conjugate pad was omitted, the antibody-reporter molecule conjugates were mixed into the sample with an appropriate amount [33,34,[45][46][47].When the liquid passes through the conjugates reservoir, the antibody-reporter molecule conjugates are slowly released. Few antibodies start to bind with the antigen and move together to the test zone.…”
Section: Competitive Formatmentioning
confidence: 99%
See 1 more Smart Citation
“…This contains target-specific antibody-reporter molecule conjugates. In cases where the conjugate pad was omitted, the antibody-reporter molecule conjugates were mixed into the sample with an appropriate amount [33,34,[45][46][47].When the liquid passes through the conjugates reservoir, the antibody-reporter molecule conjugates are slowly released. Few antibodies start to bind with the antigen and move together to the test zone.…”
Section: Competitive Formatmentioning
confidence: 99%
“…The compounds with carboxylic acid and hydroxyl functional groups are usually conjugated by a carbodiimidemediated reaction [33,34,47,[95][96][97][98][99][100][101][102], whereas compounds with active hydrogen, e.g., α-picolines, ketones, esters, and acetylenes, can be conjugated to an amine or amide group of the carrier by a Mannich reaction [103,104]. Furthermore, structure modifications of the parent compounds to add the reactive functional group to the molecule can be conducted when necessary.…”
Section: Production Of Hapten-carrier Moleculesmentioning
confidence: 99%
“…In addition, in 2018, China formulated the national standard of HPLC for the determination of AA‐A in cosmetics (GB/T 35949–2018), which has a detection limit of 0.3 mg/kg and a quantification limit of 1.0 mg/kg. At present, the detection methods employed for AA‐A include ultraviolet spectrophotometry, thin‐layer scanning, 22 thin‐layer ultraviolet spectrophotometry, HPLC, 23 liquid chromatography tandem‐mass spectrometry (LC/MS/MS), 24,25 capillary electrophoresis, 26 nuclear magnetic resonance, 27 and enzyme‐linked immunosorbent methods 28 . Instrumentation‐based detection methods are advantageous, owing to their high sensitivities and good reproducibilities.…”
Section: Introductionmentioning
confidence: 99%
“…Although this method showed high sensitivity and specificity, it was still limited by the fact that the polyclonal antibody had poor reproducibility and stability. Immunochromatographic assay strips have been widely employed for semiquantitative, qualitative detection, and mass sample screening due to their sensitivity and convenience Kong, Xie, Liu, Song, Kuang, Cui et al, 2017;Lei, Xu, Song, Liu, & Kuang, 2018;Li, Wu, Song, Zheng, & Kuang, 2019).…”
Section: Introductionmentioning
confidence: 99%