2009
DOI: 10.1016/j.steroids.2009.06.007
|View full text |Cite
|
Sign up to set email alerts
|

Development of highly sensitive quantification method for testosterone and dihydrotestosterone in human serum and prostate tissue by liquid chromatography–electrospray ionization tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
63
2
1

Year Published

2010
2010
2017
2017

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 94 publications
(70 citation statements)
references
References 34 publications
4
63
2
1
Order By: Relevance
“…The E2 obtained was assayed by LC-MS/MS after derivatization, as described previously (Arai et al 2010). The androgen fraction was derivatized to the picolinoyl ester and assayed by LC-MS/MS (Yamashita et al 2009). The lowest analytical limits for DHEA, androstenedione, T, E2, and P4 were 10, 10, 2, 0.1, and 10 pg/assay, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…The E2 obtained was assayed by LC-MS/MS after derivatization, as described previously (Arai et al 2010). The androgen fraction was derivatized to the picolinoyl ester and assayed by LC-MS/MS (Yamashita et al 2009). The lowest analytical limits for DHEA, androstenedione, T, E2, and P4 were 10, 10, 2, 0.1, and 10 pg/assay, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…It has generally been proposed that the presence of interference peaks co-existing in biological matrixes and co-eluting with the analyte of interest caused ionization suppression, reducing the detection sensitivity (12,13). For the measurement of steroids in organs, LC-MS analysis has several advantages over immunoassays, including a better specificity and the ability to quantify numerous steroids in a single run (14,15). Especially, liquid chromatographyelectrospray ionization time-of-flight mass spectrometry (LC-TOFMS) made possible to perform the accurate mass determination of components containing matrixes.…”
mentioning
confidence: 99%
“…The reagent solution was used after 3-5 min [5]. Serum prostate-specific antigen (PSA) levels were measured using a DPC Imrise third generation PSA assay kit.…”
Section: Chemicals and Materialsmentioning
confidence: 99%
“…Serum hormone levels were determined by LC-MS/MS, as described by Yamashita et al [5]. T and DHT levels in prostate tissue samples were measured using an API-5000 triple-stage quadrupole mass spectrometer (Applied Biosystems, Foster City, CA, USA) connected to a Shimadzu LC-20 AD pump and Shimadzu SIL HTC autosampler (Shimadzu, Kyoto, Japan) and an electrospray ionization (ESI) ion-source device.…”
Section: Lc-ms/msmentioning
confidence: 99%
See 1 more Smart Citation