1982
DOI: 10.1021/jf00113a035
|View full text |Cite
|
Sign up to set email alerts
|

Development of enzyme-linked immunosorbent assays for residue analysis of diflubenzuron and BAY SIR 8514

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
14
0
2

Year Published

1988
1988
2005
2005

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 45 publications
(16 citation statements)
references
References 17 publications
0
14
0
2
Order By: Relevance
“…Antisera 1338 and 1339 were raised against BKLH and 2114BKLH and ,1973BKLH and ,1974BKLH and ,1975, and 1567 against 8KLH. certain coating antigedantibody combinations (Wie and Hammock, 1982).…”
Section: Resultsmentioning
confidence: 99%
“…Antisera 1338 and 1339 were raised against BKLH and 2114BKLH and ,1973BKLH and ,1974BKLH and ,1975, and 1567 against 8KLH. certain coating antigedantibody combinations (Wie and Hammock, 1982).…”
Section: Resultsmentioning
confidence: 99%
“…The affinity of the antibodies produced in response to the phenyl-, 4-chlorophenyl-, and succinamidophenylurea immunogens (designated 0-C1, 1-C1, and DM antisera respectively) for the coating protein was much higher than for monuron, diuron, or fenuron, so that competitive inhibition was not evident at herbicide concentrations up to 400 ng/ml. This phenomenon, possibly due to bivalent binding of the antibody to the coating protein, has been encountered with other systems such as in the assay for diflubenzuron (Wie & Hammock, 1982) and has been investigated in detail by Kemp & Morgan (1986) and by Vos et al (1987). Attempts to decrease the effect by reduction of the concentration of coating protein or production of Fab fragments of antibody by pepsin digestion as described (Kemp & Morgan, 1986) were unsuccessful.…”
Section: Resultsmentioning
confidence: 99%
“…These procedures offer rapid analyses with a minimum of sample preparation and often have sufficient specificity to provide a method capable of screening large numbers of samples efficiently. Although haptens have been synthesized and antibodies developed for benzoyl-phenylurea insecticides (Wie & Hammock, 1982), no such assays have been developed for phenylurea herbicides. The present study was initiated to provide these antibodies and to explore the feasibility of assaying these compounds in foods.…”
Section: Introductionmentioning
confidence: 99%
“…No início dos anos 80, começou-se a discutir as possibilidades que estes tipos de métodos analíticos podiam oferecer na detecção de contaminantes, tanto em amostras ambientais como de alimentos 12,14-16 , o que fomentou a sua aplicação no campo da química ambiental. A partir desse momento, começou-se a utilizar a marcação enzimática, que proporcionava menores riscos e apresentava sensibilidade similar aos métodos convencionais de análise 12,[15][16][17][18][19] . Inúmeras vantagens podem ser obtidas com a utilização dos métodos imunoquímicos e, paulatinamente, vão sendo disponibilizadas informações sobre diversos aspectos analíticos, tais como i) interpretação dos dados obtidos no desenvolvimento dos métodos; ii) estratégias utilizadas para a garantia da qualidade dos procedimentos operacionais; iii) análise dos dados e das informações lançadas em forma de relatórios técnicos, e iv) controle de qualidade para a melhoria da confiabilidade dos métodos, incluindo os ensaios para validação.…”
Section: Introductionunclassified
“…Os ensaios imunoenzimáticos ("enzyme immunoassay, EIA") surgiram na década de 60 para identificação e localização de antígenos em preparações histológicas 2,6,7 , tendo sido a sua utilidade reconhecida posteriormente em outros campos distintos [8][9][10][11][12][13] . No início dos anos 80, começou-se a discutir as possibilidades que estes tipos de métodos analíticos podiam oferecer na detecção de contaminantes, tanto em amostras ambientais como de alimentos 12,[14][15][16] , o que fomentou a sua aplicação no campo da química ambiental. A partir desse momento, começou-se a utilizar a marcação enzimática, que proporcionava menores riscos e apresentava sensibilidade similar aos métodos convencionais de análise 12,[15][16][17][18][19] .…”
Section: Introductionunclassified