2016
DOI: 10.1063/1.4953453
|View full text |Cite
|
Sign up to set email alerts
|

Development of an X-ray fluorescence holographic measurement system for protein crystals

Abstract: Experimental procedure and setup for obtaining X-ray fluorescence hologram of crystalline metalloprotein samples are described. Human hemoglobin, an α2β2 tetrameric metalloprotein containing the Fe(II) heme active-site in each chain, was chosen for this study because of its wealth of crystallographic data. A cold gas flow system was introduced to reduce X-ray radiation damage of protein crystals that are usually fragile and susceptible to damage. A χ-stage was installed to rotate the sample while avoiding inte… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
32
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6

Relationship

6
0

Authors

Journals

citations
Cited by 28 publications
(32 citation statements)
references
References 35 publications
0
32
0
Order By: Relevance
“…For the XFH measurement, the large COHbA crystal was briefly soaked in CO-saturated 2.30 M phosphate buffer containing 0.958 M NaH2PO4, 1.342 M K2HPO4, and 15% (v/v) glycerol, and then flash cooled to 100 K to reduce X-ray radiation damage (Figure 8a). The first XFH data-set using a COHbA crystal was collected at the beamline BL6C of Photon Factory [13]. A step-scan data collection was performed with an interval of 0.25° and 1.0° in pitch and yaw, respectively.…”
Section: Extremely Large-volume (>100 MM 3 ) Hb Crystal Growth For X-mentioning
confidence: 99%
See 4 more Smart Citations
“…For the XFH measurement, the large COHbA crystal was briefly soaked in CO-saturated 2.30 M phosphate buffer containing 0.958 M NaH2PO4, 1.342 M K2HPO4, and 15% (v/v) glycerol, and then flash cooled to 100 K to reduce X-ray radiation damage (Figure 8a). The first XFH data-set using a COHbA crystal was collected at the beamline BL6C of Photon Factory [13]. A step-scan data collection was performed with an interval of 0.25° and 1.0° in pitch and yaw, respectively.…”
Section: Extremely Large-volume (>100 MM 3 ) Hb Crystal Growth For X-mentioning
confidence: 99%
“…We checked the crystal quality by measuring the Bragg diffraction pattern for X-rays incident on the crystal (Figure 8c). More details of the XFH measurement are described in elsewhere [13]. Note that the crystals grown at the 3 ) was mounted on a customized loop made by a polyimide film (0.125 mm thickness) with a copper wire (1.2 mm diameter), and cooled to 100 K by nitrogen gas flow; (b) Typical hologram pattern of the COHbA crystal (excited by 7.25 keV X-ray photons), represented as a stereographic projection of an interference pattern in the reciprocal space (a*, b*, c*) after applying a Gaussian low path spatial filter [13]; (c) An X-ray diffraction pattern of the COHbA crystal used for the XFH measurement.…”
Section: Extremely Large-volume (>100 MM 3 ) Hb Crystal Growth For X-mentioning
confidence: 99%
See 3 more Smart Citations