2013
DOI: 10.1117/12.2027303
|View full text |Cite
|
Sign up to set email alerts
|

Development of an in-vacuum x-ray microscope with cryogenic sample cooling for beamline P11 at PETRA III

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
23
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 30 publications
(23 citation statements)
references
References 0 publications
0
23
0
Order By: Relevance
“…The characteristics of the three MX beamlines at PETRA III are summarized in Table 1. 2.2. Beamline P11 @ DESY DESY beamline P11 provides two state-of-the-art endstations for structural investigations of biological samples at different length scales: an X-ray microscope with a resolution of up to 10 nm [9,10,11] and a crystallography experiment. The crystallography endstation (shown in Figure 2) is operated between 5.5 keV and 30 keV and provides full SAD/MAD capability.…”
Section: 1overviewmentioning
confidence: 99%
“…The characteristics of the three MX beamlines at PETRA III are summarized in Table 1. 2.2. Beamline P11 @ DESY DESY beamline P11 provides two state-of-the-art endstations for structural investigations of biological samples at different length scales: an X-ray microscope with a resolution of up to 10 nm [9,10,11] and a crystallography experiment. The crystallography endstation (shown in Figure 2) is operated between 5.5 keV and 30 keV and provides full SAD/MAD capability.…”
Section: 1overviewmentioning
confidence: 99%
“…CuTCNPP is situated on a crystallographic centre of symmetry and exhibits an r.m.s. deviation from exact molecular C 2h point group symmetry of 0.047 Å , as calculated with MOLSYM in PLATON (Spek, 2009 Computer programs: P11 Crystallography Control (Meents et al, 2013), XDS (Kabsch, 2010), SUPERFLIP (Palatinus & Chapuis, 2007), EDMA (Palatinus et al, 2012), SHELXL2014 (Sheldrick, 2015), DIAMOND (Brandenburg, 2014) and enCIFer (Allen et al, 2004).…”
Section: Resultsmentioning
confidence: 99%
“…Collection of X-ray diffraction data, structure determination and refinement X-ray diffraction data were recorded on beamline P11 (Meents et al 2013) of Petra III at the DESY (Hamburg, Germany) and on beamline 14.2 (Mueller et al 2012) of the BESSY II electron storage ring (Berlin-Adlershof, Germany). Integration of X-ray data and space group assignment was carried out with XDS (Kabsch 2010).…”
Section: Crystallizationmentioning
confidence: 99%