2012
DOI: 10.1103/physrevstab.15.083501
|View full text |Cite
|
Sign up to set email alerts
|

Development of an advanced electropolishing setup for multicell high gradient niobium cavities

Abstract: Reproducible operation at high performances of superconducting cavities is required for linear accelerators. High beta elliptical cavities are thus of concern and, to achieve required performances for such resonators, surface preparation including electropolishing is recommended. We have designed and operate a setup for electropolishing in the vertical position of multicell cavities in order to: (i) obtain high yield with large elliptical cavities for Superconducting Linac (SPL) or European Spallation Source p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
15
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(16 citation statements)
references
References 4 publications
(8 reference statements)
1
15
0
Order By: Relevance
“…The same set of parameters (6 V − 20 L= min − T < 20°C) was applied on a nine-cell cavity: 50 μm on average were removed from the "TB9R1025" ILC cavity from Fermi Accelerator National Laboratory (FERMILAB), previously horizontally electropolished. A large cathode diameter (50 mm) was used for nine-cell VEP experiments in [5] in order to decrease the anodic current density. The diameter was reduced down to 40 mm for this experiment in order to avoid contact with HOM antennas during insertion.…”
Section: B Results On a Ilc Nine-cell Cavitymentioning
confidence: 99%
See 4 more Smart Citations
“…The same set of parameters (6 V − 20 L= min − T < 20°C) was applied on a nine-cell cavity: 50 μm on average were removed from the "TB9R1025" ILC cavity from Fermi Accelerator National Laboratory (FERMILAB), previously horizontally electropolished. A large cathode diameter (50 mm) was used for nine-cell VEP experiments in [5] in order to decrease the anodic current density. The diameter was reduced down to 40 mm for this experiment in order to avoid contact with HOM antennas during insertion.…”
Section: B Results On a Ilc Nine-cell Cavitymentioning
confidence: 99%
“…Vertical electropolishing at a voltage of 20 V has already been investigated on single-cell cavities [5], and a gradient of 30 MV=m has been achieved. In a second step, single-cell cavities have been electropolished with parameters derived from standard horizontal EP: (i) moderate acid flow (8 L= min); (ii) voltage above 12 V; (iii) temperature around 30°C.The electrolyte is a mixture of HFð40w%Þ − H 2 SO 4 ð96w%Þ in volume proportions of 1 to 9.…”
Section: Parameters Study On Single-cell 1300 Mhz Tesla-shaped Camentioning
confidence: 99%
See 3 more Smart Citations