The platform will undergo maintenance on Sep 14 at about 7:45 AM EST and will be unavailable for approximately 2 hours.
2004
DOI: 10.1016/j.chroma.2004.04.016
|View full text |Cite
|
Sign up to set email alerts
|

Development of an accelerated low-pH reversed-phase liquid chromatography column stability test

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0
1

Year Published

2005
2005
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(9 citation statements)
references
References 19 publications
0
8
0
1
Order By: Relevance
“…Retention factors of the solutes in their protonated form are often lower than when the solute is neutral. Also bonded‐phase columns are unstable at low pH 12, 13. However, analyses conducted with acidic mobile phases have become popular using anionic additives such as ClO 4 − and CF 3 COO − to increase the retention and the selectivity of cationic solutes in RP‐HPLC 14.…”
Section: Introductionmentioning
confidence: 99%
“…Retention factors of the solutes in their protonated form are often lower than when the solute is neutral. Also bonded‐phase columns are unstable at low pH 12, 13. However, analyses conducted with acidic mobile phases have become popular using anionic additives such as ClO 4 − and CF 3 COO − to increase the retention and the selectivity of cationic solutes in RP‐HPLC 14.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, for stability testing at low pH, it is necessary to monitor the retention factors since, in this particular case, the degradation processes involve the acid-catalyzed hydrolysis of Si-O-Si bonds between the chromatographic support and the organosilane layer and, consequently, loss of the bonded phase and retention [38]. Up to now, the stability tests performed on the titanized phases have been carried out in basic mobile phases due the possible advantages of a protective TiO 2 layer on the silica support in alkaline medium [21 (Silva, C. R., Airoldi, C., Collins, K. E., Collins, C. H., J. Chromatogr.…”
Section: Stability Testingmentioning
confidence: 99%
“…5,6,9,37,38,[72][73][74][75] Por sua vez, a sílica é um material extremamente estável em meio ácido, mas as ligações siloxano no ligante utilizado para modificar a sílica quimicamente (Si-C) são hidrolisadas em meio ácido. 5,6,9,37,38, 75,76 Estabilidade em fase móvel alcalina Os testes de estabilidade são feitos em condições semelhantes às condições comumente usadas (pH da fase aquosa entre 2 e 8, concentração de tampão entre 5 e 25 mmol/L e temperaturas entre 20 e 40 °C) ou em condições extremas para acelerar a degradação da fase estacionária (pH da fase aquosa extremamente ácido em 0,5 a 1,5 ou extremamente alcalino em 10 a 14, concentração de tampão de 50 a 200 mmol/L e temperaturas entre 23 e 150 °C), sendo que o primeiro caso representa melhor a estabilidade das fases estacionárias. A degradação da fase estacionária é avaliada em função da passagem de fase móvel pela coluna, sendo representada em volumes de coluna (Vc) ou pelo tempo em que a fase móvel passa pela coluna 5,6,37,38,75 Muitas tentativas foram feitas para aumentar a estabilidade das fases estacionárias em condições alcalinas.…”
Section: Estabilidade Das Fases Estacionáriasunclassified