2000
DOI: 10.1016/s0021-9673(99)00861-4
|View full text |Cite
|
Sign up to set email alerts
|

Development of a new cyano-bonded column for high-performance liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
12
0
1

Year Published

2004
2004
2018
2018

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 20 publications
1
12
0
1
Order By: Relevance
“…2) shows several interesting groupings based on a rescaled distance below 3, for example, C 18 and zorbax columns were grouped together, which is in agreement with the manufacturer's claims. The same conclusions are obtained for C 8 and monolithic columns, which could be attributed to lower SDS sorption because of the higher bonding chain density of the stationary phase used. Amino and phenyl columns are in the same dendrogram group due to the fact that both display similar characteristics (% C load).…”
Section: Dendrogramsupporting
confidence: 72%
See 1 more Smart Citation
“…2) shows several interesting groupings based on a rescaled distance below 3, for example, C 18 and zorbax columns were grouped together, which is in agreement with the manufacturer's claims. The same conclusions are obtained for C 8 and monolithic columns, which could be attributed to lower SDS sorption because of the higher bonding chain density of the stationary phase used. Amino and phenyl columns are in the same dendrogram group due to the fact that both display similar characteristics (% C load).…”
Section: Dendrogramsupporting
confidence: 72%
“…Cyano columns are less commonly used, in part because of concerns about their stability [8] and reproducibility. [9] A common observation is that cyano columns are less retentive (i.e.…”
Section: Column Selectionmentioning
confidence: 99%
“…Some of the characteristics according to the manufacturer are the low hydrophobicity for rapid elution of hydrophobic molecules, the retention and separation of strongly basic analytes, the compatibility with highly percent of aqueous mobile phases and its excellent stability and reproducibility. It has been previously described that the properties of the CN columns are governed by the type of cyano phase (trifunctional or monofunctional) on the silica gel support and endcapping [12,13]. Therefore, a very different column was tested.…”
Section: Resultsmentioning
confidence: 99%
“…It has been previously described that the properties of the CN columns are governed by the type of cyano phase (trifunctional or monofunctional) on the silica gel support and endcapping [10,11]. Therefore, a very different column was tested.…”
Section: Resultsmentioning
confidence: 99%