Development of a low-cost, simple, fast and quantitative lateral-flow immunochromatographic assay (ICA) strip for melatonin in health foods

Abstract: Melatonin (MT) is a hormone secreted by the pineal gland which regulates sleep rhythm and is widely used in health foods. However, MT is sometimes added illegally and excessively in certain health foods, which might cause undesirable side-effects. In this work, an easy-to-use immunochromatographic assay (ICA) based on mouse monoclonal antibody (mAb) for rapid detection of MT was developed for the purpose of safety. Under the optimal conditions, the developed ICA exhibited a visual limit of detection (VLOD) of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(7 citation statements)
references
References 25 publications
(21 reference statements)
0
6
0
Order By: Relevance
“…Recently, an immunochromatographic assay (ICA) was developed for rapid quantitative melatonin detection using AuNPs conjugated to mouse monoclonal antibodies. 171 The ICA yielded a LOD of 0.185 µM as determined by eye, and a LOD of 215.25 nM as determined using a strip reader, for pharmaceutical melatonin samples measured under optimized experimental conditions. The linear detection range was from 215.25 nM to 42 μM, which was comparable to standard liquid chromatography.…”
Section: Optical Detection Of Melatoninmentioning
confidence: 94%
See 1 more Smart Citation
“…Recently, an immunochromatographic assay (ICA) was developed for rapid quantitative melatonin detection using AuNPs conjugated to mouse monoclonal antibodies. 171 The ICA yielded a LOD of 0.185 µM as determined by eye, and a LOD of 215.25 nM as determined using a strip reader, for pharmaceutical melatonin samples measured under optimized experimental conditions. The linear detection range was from 215.25 nM to 42 μM, which was comparable to standard liquid chromatography.…”
Section: Optical Detection Of Melatoninmentioning
confidence: 94%
“…On the other hand, SWV is usually applied in reversible systems and rapid reaction kinetics systems. [171] an electrochemical sensor containing nitrogen-doped ordered mesoporous carbon/Nafion/glassy carbon electrode (GCE) for the highly sensitive and selective detection of tryptophan. Cyclic voltammogram exhibited a linear increase in the oxidation current with tryptophan concentration in the range of 0.5-70.0 μM, with a LOD of 35.0 nM.…”
Section: Electrochemical Detection Of Tryptophan and Melatoninmentioning
confidence: 99%
“…The LFIA strip was assembled as previously reported. 29 As shown in Fig. 1a, the strip consisted of a PVC backing card, an NC membrane with a test line (T line) and a control line (C line), a release pad, a sample pad, and an absorbent pad.…”
Section: Methodsmentioning
confidence: 99%
“…The produced artificial antigens were used for animal immunization described in our previous study [32]. The production of mAb was followed by our previous publication [33]. The obtained mAb was purified by protein G and stored at −20 • C.…”
Section: Production Of Monoclonal Antibodymentioning
confidence: 99%