2008
DOI: 10.1016/j.jchromb.2007.11.009
|View full text |Cite
|
Sign up to set email alerts
|

Development of a liquid chromatography–tandem mass spectrometry method for the determination of 23 endogenous steroids in small quantities of primate urine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
81
0
2

Year Published

2009
2009
2021
2021

Publication Types

Select...
8
1

Relationship

5
4

Authors

Journals

citations
Cited by 129 publications
(90 citation statements)
references
References 42 publications
5
81
0
2
Order By: Relevance
“…We successfully measured all but three Taï samples for cortisol following Hauser et al (2008). However, we corrected cortisol levels of chimpanzee urine samples using deuterated testosterone because a coelution at the retention time of the traditional internal standard for cortisol, prednisolone, prevented us from using this standard.…”
Section: Laboratory Analysesmentioning
confidence: 99%
“…We successfully measured all but three Taï samples for cortisol following Hauser et al (2008). However, we corrected cortisol levels of chimpanzee urine samples using deuterated testosterone because a coelution at the retention time of the traditional internal standard for cortisol, prednisolone, prevented us from using this standard.…”
Section: Laboratory Analysesmentioning
confidence: 99%
“…Liquid chromatography-tandem mass spectrometry was used to measure urinary cortisol levels (Hauser et al, 2008). Furthermore, each sample was analyzed for creatinine concentrations to correct cortisol measurements for water content in the urine, which varies with the time since the last urination and the level of an animal's hydration (Erb et al, 1970).…”
Section: Urine Sample Collection and Analysismentioning
confidence: 99%
“…Samples were spiked before purification with the same mixture of internal standards used for the calibration curve, at 50 ng/ml final extract (for detailed information, see Hauser et al (2008)). A mixture of 500 ml urine and 500 ml distilled water (Aqua B. Braun, Melsungen, Germany) was loaded onto a polymer-based reversed phase cartridge (Chromabond HR-X, 30 mg, Macherey-Nagel, Duren, Germany).…”
Section: Solid-phase Extractionmentioning
confidence: 99%
“…We used a Waters Alliance 2695 separation module equipped with a quaternary pump and column oven ( The MS analyses were carried out on a Quattro Premier XE tandem mass spectrometer with Z spray ESI interface (Micromass, Manchester, UK) and the settings were the same as those described in Hauser et al (2008). We examined LC-MS/MS data with MassLynx (Version 4.1; QuanLynxSoftware).…”
Section: Lc-ms/ms Measurementmentioning
confidence: 99%