2016
DOI: 10.1016/j.snb.2016.02.129
|View full text |Cite
|
Sign up to set email alerts
|

Development of a hydrogen sulfide end-of-service-life indicator for respirator cartridges using cobinamide

Abstract: An inexpensive paper-based sensor was developed for detecting low ppm concentrations of hydrogen sulfide gas. A piece of filter paper containing aquohydroxocobinamide [OH(H2O)Cbi] was placed on the end of a bifurcated optical fiber, and the reflectance spectrum of the OH(H2O)Cbi was monitored during exposure to 10.0 ppm hydrogen sulfide gas (NIOSH recommended exposure limit). Reaction of sulfide (HS−) yielded an increase in reflectance from 400–450 nm, and decrease from 470–550 nm. Spectral changes were monito… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 23 publications
0
9
0
Order By: Relevance
“…In previous studies, glass fiber filter paper demonstrated larger reflectance signals than cellulose filter paper, presumably because the glass fiber paper is thicker and allows more light to reach the detector in a reflectance configuration. , Additionally, glass fiber paper is less affected by water vapor. The optimal concentration and volume of CN­(H 2 O)­Cbi placed on the paper was found to be 15.00 ± 0.02 μL of 200.0 ± 0.2 μM.…”
Section: Resultsmentioning
confidence: 94%
See 2 more Smart Citations
“…In previous studies, glass fiber filter paper demonstrated larger reflectance signals than cellulose filter paper, presumably because the glass fiber paper is thicker and allows more light to reach the detector in a reflectance configuration. , Additionally, glass fiber paper is less affected by water vapor. The optimal concentration and volume of CN­(H 2 O)­Cbi placed on the paper was found to be 15.00 ± 0.02 μL of 200.0 ± 0.2 μM.…”
Section: Resultsmentioning
confidence: 94%
“…A previously described diffuse reflectance configuration comprising a bifurcated optical fiber, Ocean Optics miniature spectrometer, and tungsten halogen light source was used here to determine the normalized intensity of the chip-LED. , The common end of the bifurcated fiber optic was held close to the LED at different angles, to capture the average LED spectrum ( n = 3) by the spectrometer. Spectral responsivity of the on-chip LED was determined by holding a mirror directly above both the chip-LED and photodiodes and recording the RGB values.…”
Section: Materials and Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The absence of 5,6‐dimethylbenzimidazole provides Cbi‐enhanced ligand binding and redox properties , . Cbi complexes are investigated as antidotes of cyanide, hydrogen sulfide, hypotensive, and wound‐healing drugs as well as cyanide and hydrogen sulfide sensors.…”
Section: Introductionmentioning
confidence: 99%
“…Electrochemical immunoassay, which possesses the advantages of potential portability [13], low cost [14] and high sensitivity [15], has been well developed and widely applied to chemical analysis [16,17]. Moreover, magnetic beads (MBs) are extensively selected to fabricate biosensors, which benefit from their high agent immobilization due to their small-size effect, high large surface area [18], biological compatibility and various functional groups coating.…”
Section: Introductionmentioning
confidence: 99%