Development of a femoral template for computer-assisted tunnel placement in anatomical double-bundle ACL reconstruction

Abstract: Femoral graft placement is an important factor in the success of anterior cruciate ligament (ACL) reconstruction. In addition to improving the accuracy of femoral tunnel placement, Computer Assisted Surgery (CAS) can be used to determine the anatomic location. This is achieved by using a 3D femoral template which indicates the position of the anatomical ACL center based on endoscopically measurable landmarks. This study describes the development and application of this method. The template is generated through… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 49 publications
0
10
0
Order By: Relevance
“…This value is constructed from the accuracies of (1) the planning procedure using the template implemented in the CAS system and (2) the placement procedure using the real‐time navigation function of the CAS system .The accuracy of the planning procedure with the template is related to the reproducibility of the positions of the AM and PL center locations within the template. In the process of defining the template by using 31 knee specimens, this reproducibility, reflected by the standard deviations of the mean center positions, appeared to be 2.2 mm (AM) and 2.0 mm (PL) . Performing the planning procedure with the template implemented in the CAS system at the 31 knee specimen of the development study resulted in slightly worse accuracy of the template positions relative to the anatomical centers (2.5 mm for AM and 2.2 mm for PL, Table ).…”
Section: Discussionmentioning
confidence: 93%
See 3 more Smart Citations
“…This value is constructed from the accuracies of (1) the planning procedure using the template implemented in the CAS system and (2) the placement procedure using the real‐time navigation function of the CAS system .The accuracy of the planning procedure with the template is related to the reproducibility of the positions of the AM and PL center locations within the template. In the process of defining the template by using 31 knee specimens, this reproducibility, reflected by the standard deviations of the mean center positions, appeared to be 2.2 mm (AM) and 2.0 mm (PL) . Performing the planning procedure with the template implemented in the CAS system at the 31 knee specimen of the development study resulted in slightly worse accuracy of the template positions relative to the anatomical centers (2.5 mm for AM and 2.2 mm for PL, Table ).…”
Section: Discussionmentioning
confidence: 93%
“…of the AM and PL center locations within the template. In the process of defining the template by using 31 knee specimens, this reproducibility, reflected by the standard deviations of the mean center positions, appeared to be 2.2 mm (AM) and 2.0 mm (PL) (25). Performing the planning procedure with the template implemented in the CAS system at the 31 knee specimen of the development study resulted in slightly worse accuracy of the template positions relative to the anatomical centers (2.5 mm for AM and 2.2 mm for PL, Table 4).…”
Section: Discussionmentioning
confidence: 96%
See 2 more Smart Citations
“…Since the QTB graft had one bone block, only one tunnel had to be made. Using the specifically developed 3D femoral template [24], incorporated in the ACL-module (MEM Institute for Biomechanics, Switzerland), the tunnel was positioned at the anatomical center of the ACL. Therefore the surface of the notch and the posterior joint cartilage edge at the medial wall in the lateral notch were digitized.…”
Section: Methodsmentioning
confidence: 99%