2003
DOI: 10.1080/0306731021000050877
|View full text |Cite
|
Sign up to set email alerts
|

Development of a Disposable Electrochemical Immunosensor for Detection of the Herbicide Acetochlor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0
3

Year Published

2005
2005
2010
2010

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 0 publications
0
6
0
3
Order By: Relevance
“…A simplification on the assay procedure in terms of operator intervention can be achieved coupling immunosensor devices with flow systems [91,109,137,138,142,146,149,155]. Working with a flow system the procedure can be automated and the analysis performed continuously and quickly, but the systems become instrumentally more complex and none of the assay steps are removed.…”
Section: Immunosensor Formatsmentioning
confidence: 99%
See 1 more Smart Citation
“…A simplification on the assay procedure in terms of operator intervention can be achieved coupling immunosensor devices with flow systems [91,109,137,138,142,146,149,155]. Working with a flow system the procedure can be automated and the analysis performed continuously and quickly, but the systems become instrumentally more complex and none of the assay steps are removed.…”
Section: Immunosensor Formatsmentioning
confidence: 99%
“…The second strategy is most frequently used, but also requires the use of extreme pH solutions such as citric acid [146], NaOH À NaCl pH 12 [158,159] , citrate -phosphate pH 4.6 [110], phosphate pH 2.1 [109], pepsin pH 2.1 [155] or fluoride acid [160].…”
Section: Immunosensor Regenerationmentioning
confidence: 99%
“…Earlier, we developed immunochemical methods for the determination of acetochlor by ELISA [22] and with the use of an immunosensor [23] or a piezosensor [24]. However, these are multistep procedures, and the time of analysis is 2 to 3 h. Moreover, ELISA includes a number of steps of pipetting and washing with the use of several specific reagents; it requires qualified personnel.…”
Section: Acetochlormentioning
confidence: 99%
“…Uma variedade de moléculas doadoras de elétrons pode reagir rapidamente com os compostos I e II, sendo que, para a enzima HRP pode-se utilizar como mediador de elétrons: hidroquinona [9,10], ácido ascórbico [11], ferroceno [12,13], iodeto [14,15,16], entre outros. O ácido 5-aminossalicílico (5-ASA) também tem sido usado como mediador para a enzima HRP em imunoensaios com detecção ótica [17], potenciométrica [18] e amperométrica [19,20,21], sendo que nos trabalhos utilizando a técnica amperométrica, a HRP foi imobilizada na superfície dos diferentes eletrodos.…”
Section: (5)unclassified
“…A molécula do mediador escolhido deve reagir rapidamente com a peroxidase oxidada. Uma variedade de moléculas doadoras de elétrons pode reagir rapidamente com os compostos I e II, sendo que, para a enzima HRP pode-se utilizar como mediador de elétrons: hidroquinona [9,10] [19,20,21], sendo que nos trabalhos utilizando a técnica amperométrica, a HRP foi imobilizada na superfície dos diferentes eletrodos.O presente trabalho apresenta um estudo sobre o comportamento eletroquímico da enzima HRP sobre eletrodo de grafite utilizando o peróxido de hidrogênio como substrato enzimático e o 5-ASA como mediador da transferência eletrônica. …”
unclassified