2022
DOI: 10.52711/0974-360x.2022.00447
|View full text |Cite
|
Sign up to set email alerts
|

Development and Validation of UV Spectrophotometric Method for Doxazosin Mesylate in Bulk and Tablets

Abstract: Doxazosin mesylate (DX) is an antihypertensive agent belonging to BCS class II. There is no reported literature available on development of spectrophotometric method for its analysis in bulk and pharmaceutical dosage forms using 0.1N HCl. Thus, attempt was made to develop and validate a new UV spectrophotometric method using 0.1N HCl as the solvent for its quantitative estimation in tablets that would be fast, simple, accurate, and sensitive. DX had a maximum absorbance wavelength of 245 nm and was linear with… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
0
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 16 publications
0
0
0
Order By: Relevance
“…Furthermore, another compound predicted to have inhibitory action against cathepsin K is (S)-8-gingerol. Gingerols are the primary metabolites in Zingiber officinale and were reported to have many protective and therapeutic effects 49 . 8-Gingerol took 3.20% of white ginger and 4.64% of yellow ginger extract composition, while 6-gingerol was the most abundant, took up 27.56% and 33.96% of sample composition in white and yellow ginger extract, respectively 50 .…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, another compound predicted to have inhibitory action against cathepsin K is (S)-8-gingerol. Gingerols are the primary metabolites in Zingiber officinale and were reported to have many protective and therapeutic effects 49 . 8-Gingerol took 3.20% of white ginger and 4.64% of yellow ginger extract composition, while 6-gingerol was the most abundant, took up 27.56% and 33.96% of sample composition in white and yellow ginger extract, respectively 50 .…”
Section: Discussionmentioning
confidence: 99%
“…The proposed method was validated for the following parameters as per International Council for Harmonisation (ICH) guidelines [16][17][18][19][20] . Accuracy: Accuracy of the method was estimated by standard addition recovery method.…”
Section: Methods Validationmentioning
confidence: 99%
“…5 ml was taken and volume was raised to 25 ml with methanol and the reading was taken at 282 nm wavelength using UV/VIS Spectrophotometer against methanol as blank. Percentage gingerol present in ginger extract was calculated from reference UV Spectra of Standard Gingerol (Shukla et al, 2012). The mean data were statistically analysed using IBM SPSS Software, Version 26.…”
Section: Data Recording and Analysismentioning
confidence: 99%