2017
DOI: 10.1016/j.arabjc.2013.11.051
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of stability-indicating RP-HPLC method for the determination of Levocabastine HCl in bulk drug and in ophthalmic suspensions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 1 publication
0
2
0
Order By: Relevance
“…HPTLC has higher sensitivity than TLC but less sensitive than HPLC. [32][33][34][35][36][37][38][39][40][41][42] Rufinamide, Roflimilast, Pragabalin, Nizatidine, Naftopidil, Dexamethasone and Moxifloxacin, Levocabastine, AMLO-VAL-HCTZ, Eremantholide C, Silymerin and curcumin, Sofosbuvir and Ledipasvir, n-acetyl cysteine, HPLC -DAD SIM [43][44][45][46][47][48][49][50][51][52][53][54] Diclofenac, Piracetam, Rivaroxaban, Ofloxacine & ornidazole UPLC SIM [55][56][57][58] Isoflavone aglycone in soybean UFLC SIM 59 Desonide HPTLC SIM 60 Loratadine, Clobetasol, TLC SIM [61][62] Nicardipine, Azilsartan medoxomil Pottasium, HPLC-MS SIM [63][64] Ezetimibe, Simavastatin, Zidovudine HPLC-MS/MS SIM [65][66][67] HPTLC has advantages over large no of the sample can apply on a single plate, and the amount of mobile phase required is small, so it has costeffective analysis. HPLC UV method is the most commonly used method for development of stability indicating method, but it has a limit of its detection ability; however it is more sensitive than TLC and HPTLC method.…”
Section: Analytical Instrument Used In Stability Indicating Methods Dementioning
confidence: 99%
“…HPTLC has higher sensitivity than TLC but less sensitive than HPLC. [32][33][34][35][36][37][38][39][40][41][42] Rufinamide, Roflimilast, Pragabalin, Nizatidine, Naftopidil, Dexamethasone and Moxifloxacin, Levocabastine, AMLO-VAL-HCTZ, Eremantholide C, Silymerin and curcumin, Sofosbuvir and Ledipasvir, n-acetyl cysteine, HPLC -DAD SIM [43][44][45][46][47][48][49][50][51][52][53][54] Diclofenac, Piracetam, Rivaroxaban, Ofloxacine & ornidazole UPLC SIM [55][56][57][58] Isoflavone aglycone in soybean UFLC SIM 59 Desonide HPTLC SIM 60 Loratadine, Clobetasol, TLC SIM [61][62] Nicardipine, Azilsartan medoxomil Pottasium, HPLC-MS SIM [63][64] Ezetimibe, Simavastatin, Zidovudine HPLC-MS/MS SIM [65][66][67] HPTLC has advantages over large no of the sample can apply on a single plate, and the amount of mobile phase required is small, so it has costeffective analysis. HPLC UV method is the most commonly used method for development of stability indicating method, but it has a limit of its detection ability; however it is more sensitive than TLC and HPTLC method.…”
Section: Analytical Instrument Used In Stability Indicating Methods Dementioning
confidence: 99%
“…Peak purity results were greater than 0.99, which indicates that the peaks are homogeneous in all stress conditions tested and thus establishing the specificity and confirming the stabilityindicating power of the developed method. 13,14 …”
Section: Forced Degradation Studiesmentioning
confidence: 99%