2018
DOI: 10.1080/22297928.2018.1429305
|View full text |Cite
|
Sign up to set email alerts
|

Development and Validation of QbD-Driven Bioanalytical LC-MS/MS Method for the Quantification of Paracetamol and Diclofenac in Human Plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 39 publications
0
4
0
Order By: Relevance
“…can be used for robustness testing, small changes in CMPs (flow rate, organic modifier percentage, column temperature, wavelength, etc.) are tested, to evaluate if they have significant effects on CMAs (40,61).…”
Section: Table I Most Frequently Used Methods In Experimental Designsmentioning
confidence: 99%
See 1 more Smart Citation
“…can be used for robustness testing, small changes in CMPs (flow rate, organic modifier percentage, column temperature, wavelength, etc.) are tested, to evaluate if they have significant effects on CMAs (40,61).…”
Section: Table I Most Frequently Used Methods In Experimental Designsmentioning
confidence: 99%
“…In order to better visualize the effects of the input variables (such as pH, temperature, flow rate, etc.) on CMAs, response surface analysis (2D or 3D response surface plot) can be applied, which shows the complex, non-linear interactions between the studied factors on quality performances (42,61). A general workflow presenting the steps of AQbD is illustrated in Scheme 2 (28,62,63).…”
Section: Table I Most Frequently Used Methods In Experimental Designsmentioning
confidence: 99%
“…BBD has an advantage over other designs that it requires less number of experiments, thus considerably saving time and effort [18, 19]. A score of research reports is the testimony of having demonstrated the utility of experimental designs in analytical method development [20–31]. For the present study survey of literature revealed that not a single bioanalytical method for ARIP assessed the robustness using the DoE approach which in turn may influence method performance over time.…”
Section: Introductionmentioning
confidence: 96%
“…Additionally, these techniques offer minimal data on how the different parameters listed above interact with, and ultimately influence, each other. In the past, research has been conducted on the development and application of retaliation surface methodologies for the quantification of various compounds [23][24][25][26][27][28][29][30][31][32][33][34]. Therefore, this research was focused on the development of a Box-Behnken-optimized RP-HPLC method for the quantification of domperidone and lansoprazole in new and unusual solvent systems.…”
Section: Introductionmentioning
confidence: 99%