2014
DOI: 10.4172/2157-7064.1000230
|View full text |Cite
|
Sign up to set email alerts
|

Development and Validation of HPLC Method for Simultaneous Estimation of Brimonidine Tartrate and Timolol Maleate in Bulk and Pharmaceutical Dosage Form

Abstract: Brimonidine tartrate and Timolol Maleate are used in treatment of glaucoma by decreasing intra ocular pressure. A validated HPLC method was developed for the assay of them. The method was performed on BDS HYPERSIL Cyano column (250×4.6 mm, 5 μ) and the mobile phase consisted of Ammonium acetate (pH 5.0, 0.01 M) -Methanol (40:60, V/V) which pumped at a flow rate equals to 1.5 ml/min at ambient temperature. 20 µl of drugs sample solutions were monitored at two fixed wavelengths (lambda=254.0 nm for Brimonidine T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 22 publications
0
6
0
Order By: Relevance
“…In comparison with the reported methods for TM/BM mixture, the proposed method was 2 times more sensitive for TM and 5, 2 and 2.5 times more sensitive for BM than the reported HPLC methods [ 30 , 31 , 33 , respectively]. While the proposed method was 100 times more sensitive for both TM and BM than the reported HPTLC method [ 35 ].…”
Section: Discussionmentioning
confidence: 85%
See 1 more Smart Citation
“…In comparison with the reported methods for TM/BM mixture, the proposed method was 2 times more sensitive for TM and 5, 2 and 2.5 times more sensitive for BM than the reported HPLC methods [ 30 , 31 , 33 , respectively]. While the proposed method was 100 times more sensitive for both TM and BM than the reported HPTLC method [ 35 ].…”
Section: Discussionmentioning
confidence: 85%
“…Some HPLC methods [ 36 – 38 ] are also reported for the determination of TM/LP mixtures. These methods have some weaknesses such as poor sensitivity [ 30 , 31 , 33 – 37 ], narrow linearity ranges [ 30 , 31 , 33 – 35 , 38 ], poor column efficiency [ 32 ], and need for time-programmed UV detection [ 32 , 37 , 38 ], column-temperature control [ 37 ], or gradient elution [ 38 ].…”
Section: Introductionmentioning
confidence: 99%
“…Chromatographic analysis Brinzolamide and/or timolol maleate Surveying literature 2000-2019 revealed that many chromatographic analysis methods have been applied for the determination of brinzolamide as well as timolol maleate. HPLC is the most commonly applied chromatographic technique for the determination of brinzolamide and timolol maleate [44][45][46][47][48][49][50][51][52][53][54][55][56][57].…”
Section: Methods and Techniques Of Analysismentioning
confidence: 99%
“…The literature survey reveals several analytical methods for quantitative estimation of BRD in body fluids and in pharmaceutical formulations by spectrophotometry [4][5][6][7][8][9][10], liquid chromatography [11][12][13][14][15][16][17][18][19][20][21] and electrochemical methods [22][23][24].…”
Section: …………………………………………………………………………………………………… Introductionmentioning
confidence: 99%