2017
DOI: 10.1007/s00217-017-3003-2
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of a novel method for aroma dilution analysis by means of stir bar sorptive extraction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
22
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 26 publications
(24 citation statements)
references
References 30 publications
1
22
0
Order By: Relevance
“…Flavour dilution (FD)‐factors were determined by means of aroma dilution analyses. The samples were diluted after thermodesorption within the gas chromatography system by increasing the carrier gas flow (helium, 44.4 mL min −1 ) in the injection system (1:4, 1:8, 1:16, 1:32, 1:64, 1:128, 1:256, 1:512) . Two capillaries with different polarity were used: VF‐5ms (30 m, 0.25 mm ID, film thickness 0.25 μm; Agilent J&W GC Columns, Santa Clara, CA, USA) and HP‐INNOWax (30 m, 0.25 mm ID, film thickness 0.25 μm; Agilent J&W GC Columns).…”
Section: Methodsmentioning
confidence: 56%
“…Flavour dilution (FD)‐factors were determined by means of aroma dilution analyses. The samples were diluted after thermodesorption within the gas chromatography system by increasing the carrier gas flow (helium, 44.4 mL min −1 ) in the injection system (1:4, 1:8, 1:16, 1:32, 1:64, 1:128, 1:256, 1:512) . Two capillaries with different polarity were used: VF‐5ms (30 m, 0.25 mm ID, film thickness 0.25 μm; Agilent J&W GC Columns, Santa Clara, CA, USA) and HP‐INNOWax (30 m, 0.25 mm ID, film thickness 0.25 μm; Agilent J&W GC Columns).…”
Section: Methodsmentioning
confidence: 56%
“…Different SRs were used to bisect the concentrations of the injected substances. According to Trapp et al ., SRs of TDU and CIS were modified. , Splitless measurements were performed with 30 mL min –1 purge flow to split vent at 2 min in CIS and the splitless mode in TDU. The carrier gas was helium 5.0 (Nippon Gases GmbH, Hürth, Germany) with a constant flow of 1.56 mL min –1 .…”
Section: Methodsmentioning
confidence: 99%
“…SPME, SBSE, and DHS are performed in a semi-automated, non-destructive, and fast workflow with higher sensitivities for highly volatile compounds. Thereby, dilution is performed by variation of the GC system’s split ratio (SR). …”
Section: Introductionmentioning
confidence: 99%
“…Volatiles that contributed to tea aromas could be extracted through the methods such as headspace solid phase microextraction (HS‐SPME; Xu et al., 2016), solvent‐assisted flavor evaporation (Sonmezdag et al., 2019), stir bar sorptive extraction (Trapp et al., 2018), simultaneous distillation‐extraction (SDE; Xu et al., 2016). Among them, SPME was more efficient for extracting low‐molecular weight compounds, while SDE was more appropriate for extracting compounds with high boiling point (Sheibani et al., 2016).…”
Section: Introductionmentioning
confidence: 99%
“…Among them, SPME was more efficient for extracting low‐molecular weight compounds, while SDE was more appropriate for extracting compounds with high boiling point (Sheibani et al., 2016). Subsequently, the volatile compounds could be analyzed via gas chromatography–mass spectrometry (GC‐MS; Xu et al., 2016), gas chromatography‐olfactometry (GC‐O; Trapp et al., 2018), electronic nose (Rocchi et al., 2019), and gas chromatography–combustion–isotope ratio mass spectrometry (Sciarrone et al., 2018). By using these methods, more than 700 volatile compounds, including alcohols, esters, alkenes, ketones, and aldehydes were detected in various teas (Guo et al., 2018).…”
Section: Introductionmentioning
confidence: 99%