2011
DOI: 10.1016/j.aca.2011.02.032
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of a multi-residue liquid chromatography–tandem mass spectrometry confirmatory method for eleven coccidiostats in eggs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
22
0
2

Year Published

2012
2012
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 39 publications
(24 citation statements)
references
References 29 publications
0
22
0
2
Order By: Relevance
“…Just recently Boscher et al [25] and Galarini et al [22] reported on its occurrence; Boscher et al in the case of veterinary drugs (ionophores as well) in feeding stuff, and Galarini in the case of coccidiostats in eggs. The phenomenon is mainly caused by the co-eluting matrix interferences suppressing or enhancing the abundance of ions generated by the target compounds.…”
Section: Ion Suppressionmentioning
confidence: 97%
See 2 more Smart Citations
“…Just recently Boscher et al [25] and Galarini et al [22] reported on its occurrence; Boscher et al in the case of veterinary drugs (ionophores as well) in feeding stuff, and Galarini in the case of coccidiostats in eggs. The phenomenon is mainly caused by the co-eluting matrix interferences suppressing or enhancing the abundance of ions generated by the target compounds.…”
Section: Ion Suppressionmentioning
confidence: 97%
“…This approach resulted in remarkably low standard deviations but it increases the number of samples notably. Therefore, we preferred an approach similar to that of Galarini et al [22]. We used matrix calibration, but instead of using prepared blank sample as the solvent for calibration solutions, five blank yoghurt samples fortified at five different concentration levels (0.5 9 ML-5 9 ML) were included in each batch and processed the same way as the other samples were.…”
Section: Calibrationmentioning
confidence: 99%
See 1 more Smart Citation
“…Several authors used an HPLC-MS technique for single and multiresidual determination of these compounds in eggs, in muscle and in feedstuffs [18][19][20][21][22][23][24][25] reaching a lower Limit of Detection (LOD) than HPLV-UV. Sample preparation is a critical step in the analysis of coccidiostats [26], and sometimes highly specific and selective methods like immunoaffinity chromatography (IAC) can be used, [27], but this procedure, however, is very long, complex and expensive for routine analysis.…”
Section: Introductionmentioning
confidence: 99%
“…Most of the works use a chromatographic technique, especially high-performance liquid chromatography coupled with ultraviolet detector or mass spectrometric detector [14][15][16][17][18][19][20][21][22][23][24][25][26][27][28].…”
Section: Introductionmentioning
confidence: 99%