2018
DOI: 10.1016/j.jpba.2018.07.007
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of a simple chromatographic method for simultaneous determination of clindamycin phosphate and rifampicin in skin permeation studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
18
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 25 publications
(19 citation statements)
references
References 25 publications
1
18
0
Order By: Relevance
“…In the case of D6, the precision in the stratum corneum was in the range of 5.1–9.6%, with an accuracy of 92.2–101.6%; in the epidermis, precision was in the range of 5.8–9.2%, with an accuracy of 94.2–97.2%; in the dermis, precision was in the range of 5.7–6.6%, with an accuracy of 97.4–98.8%; in the receptor fluid, precision was in the range of 4.9–7.9%, with an accuracy of 97.6–103.0%. In all the above experiments, the CV was less than 15% [ 59 ]. Therefore, the recoveries indicate a very efficient extraction of the analytes and a high affinity of siloxanes to the solvent used (i.e., CCl 4 ).…”
Section: Resultsmentioning
confidence: 99%
“…In the case of D6, the precision in the stratum corneum was in the range of 5.1–9.6%, with an accuracy of 92.2–101.6%; in the epidermis, precision was in the range of 5.8–9.2%, with an accuracy of 94.2–97.2%; in the dermis, precision was in the range of 5.7–6.6%, with an accuracy of 97.4–98.8%; in the receptor fluid, precision was in the range of 4.9–7.9%, with an accuracy of 97.6–103.0%. In all the above experiments, the CV was less than 15% [ 59 ]. Therefore, the recoveries indicate a very efficient extraction of the analytes and a high affinity of siloxanes to the solvent used (i.e., CCl 4 ).…”
Section: Resultsmentioning
confidence: 99%
“…The specicity and selectivity were evaluated in order to identify compounds that might interfere with analyte elution in the chromatogram. Several components, namely PBS (pH 7.4) and skin sample, that may affect the analyte chromatogram were evaluated to ensure a good separation with minimal interference for the analytical method as highlighted by Pereira et al 26 As presented in Fig. 3, no interfering peaks were found in the chromatograms.…”
Section: Hplc Methods Validationmentioning
confidence: 99%
“…MMIPs use magnetic nanoparticles as the core covered by MIPs shell. The MMIPs can be separated from the solvent by external magnetic field due to the magnetic properties of magnetic nanoparticles [16]. It is worth reporting that their low toxicity combined with the skills above make MMIPs a qualified option in the fields of purification and separation [17].…”
Section: Magnetic Solid Phase Extraction (Mspe)mentioning
confidence: 99%