2016
DOI: 10.3390/chemosensors4040022
|View full text |Cite
|
Sign up to set email alerts
|

Development and Application of Electrochemical Sensor Based on Molecularly Imprinted Polymer and Carbon Nanotubes for the Determination of Carvedilol

Abstract: This work describes the preparation of a glassy carbon electrode (GCE) modified with molecularly imprinted polymer (MIP) and multiwalled carbon nanotubes (MWCNTs) for determination of carvedilol (CAR). Electrochemical behavior of CAR on the modified electrode was evaluated using cyclic voltammetry. The best composition was found to be 65% (m/m) of MIP. Under optimized conditions (pH 8.5 in 0.25 mol·L −1 Britton-Robinson buffer and 0.1 mol·L −1 KCl) the voltammetric method showed a linear response for CAR in th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(14 citation statements)
references
References 33 publications
0
14
0
Order By: Relevance
“…About 1.0 mg of Cr(III) ion imprinted MWCNT‐IIP was added to 1 mL of 0.5% Nafion solution and homogenized in a mortar for 10 min. Nafion solution was used in this study for the fixation of imprinted polymer to the platinum electrode surface . The final paste was fabricated on the platinum electrode surface and allowed to dry at room temperature; it is designated Pt‐MWCNT‐IIP.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…About 1.0 mg of Cr(III) ion imprinted MWCNT‐IIP was added to 1 mL of 0.5% Nafion solution and homogenized in a mortar for 10 min. Nafion solution was used in this study for the fixation of imprinted polymer to the platinum electrode surface . The final paste was fabricated on the platinum electrode surface and allowed to dry at room temperature; it is designated Pt‐MWCNT‐IIP.…”
Section: Methodsmentioning
confidence: 99%
“…Nafion solution was used in this study for the fixation of imprinted polymer to the platinum electrode surface. 14,15 The final paste was fabricated on the platinum electrode surface and allowed to dry at room temperature; it is designated Pt-MWCNT-IIP. Phosphate buffer was used in this study to supply conductivity for the paste fabricated on the platinum electrode.…”
Section: Preparation Of Mwcnt-iip Modified Platinum Electrode and Elementioning
confidence: 99%
“…(For additional information, please see references [141,144,145,148,150,151,156,160]). [183][184][185] Quartz Crystal Microbalances Piezoelectric [14,114,130,146,[186][187][188][189][190][191][192] Microfluidic devices Optical [27,128,150,[193][194][195]] Electrical [148,190] Modified electrodes Electrochemical [26,99,[152][153][154][155][196][197][198][199][200][201][202] Sensory chips Optical [161,[193][194][195] Table 2. Cont.…”
Section: New Micro and Nano Sensory Devices Based On Smart Polymersmentioning
confidence: 99%
“…Nafion is a polymeric resin with properties like chemical and thermal stability and has high selectivity towards different cations. Nafion is used in this study for the fixation of imprinted polymer on to the platinum electrode surface [18][19][20]. The mixture was carefully coated on the platinum electrode surface and dried at room temperature [21,22].…”
Section: Preparation Of Modified Platinum Electrode and Optimization mentioning
confidence: 99%