2011
DOI: 10.4028/www.scientific.net/amr.421.140
|View full text |Cite
|
Sign up to set email alerts
|

Development and Application of Advanced Coiling Temperature Control System in Hot Strip Mill

Abstract: Run out table cooling equipment and coiling temperature control (CTC) system, especially mathematic models of a hot strip mill were introduced. Heat transfer models such as air convection model, heat radiation model and laminar cooling model, process control models such as segment tracking model, feedback control model, self-learning model and case-based reasoning model were detailed described. Since online application of the new CTC system, the laminar cooling control system has been running stably and reliab… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0

Year Published

2012
2012
2015
2015

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 2 publications
0
1
0
Order By: Relevance
“…Laminar cooling control system adjusts water flow by turning on or off valves of headers. Strip is cooled from finish rolling temperature (800˚C~˚C900 ˚C) at exit of finishing mill to required coiling temperature (550˚C~700 ˚C) during laminar cooling process [7]. Control system of laminar cooling includes basic automation system and process automation system [8].…”
Section: Process and Equipment Of Laminar Coolingmentioning
confidence: 99%
“…Laminar cooling control system adjusts water flow by turning on or off valves of headers. Strip is cooled from finish rolling temperature (800˚C~˚C900 ˚C) at exit of finishing mill to required coiling temperature (550˚C~700 ˚C) during laminar cooling process [7]. Control system of laminar cooling includes basic automation system and process automation system [8].…”
Section: Process and Equipment Of Laminar Coolingmentioning
confidence: 99%
“…At present, Simulation platform technology has been widely applied in different fields, playing an indispensable and invaluable role in the industrial process control system and the design of weapon equipment system, such as the laminar cooling system. Laminar cooling system is to cool the strips from the austenitic finishing temperature (800~900℃) down to the ferrite coiling temperature (550~700℃) with an appropriate cooling rate, by controlling the applied cooling water quantity and the runout table velocity [1][2][3]. To reduce cost and meet the requirements of repeat trials, it is necessary to design and develop simulation platform [4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…5th International Conference on Advanced Design and Manufacturing Engineering (ICADME 2015) Strip is cooled from finish rolling temperature at exit of finishing mill to required coiling temperature during laminar cooling process [7]. Control system of laminar cooling includes basic automation system and process automation system [8].…”
Section: Equipment Of Laminar Coolingmentioning
confidence: 99%