2005
DOI: 10.1016/j.chroma.2005.04.056
|View full text |Cite
|
Sign up to set email alerts
|

Development and application of a new on-line SPE system combined with LC–MS/MS detection for high throughput direct analysis of pharmaceutical compounds in plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
50
0

Year Published

2006
2006
2016
2016

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 98 publications
(51 citation statements)
references
References 33 publications
1
50
0
Order By: Relevance
“…[38][39][40]44 This is critical for some applications such as pharmacokinetic studies that handle a large number of samples. Theron et al 44 described a method for quantification of EFZ in human saliva with a LLOQ of 6.11 ng mL -1 , but with a long analysis time 8.5 min.…”
Section: Discussionmentioning
confidence: 99%
“…[38][39][40]44 This is critical for some applications such as pharmacokinetic studies that handle a large number of samples. Theron et al 44 described a method for quantification of EFZ in human saliva with a LLOQ of 6.11 ng mL -1 , but with a long analysis time 8.5 min.…”
Section: Discussionmentioning
confidence: 99%
“…The lower limit of quantitation was 0.1 ng/mL and the linear calibration range was from 0.1 to 100 ng/mL for both analytes. A direct coupling of a pre-analytics module directly with a LC-MS/MS instrument is feasible as well, either by a dedicated system (Alnouti et al, 2005;Koal et al, 2006) or by implementing a HPLC injection valve onto a generic liquid handling system (Daurel-Receveur et al, 2006). A 96-well LLE LC-MS/MS method for determination of a basic and polar drug candidate from plasma samples developed (Xu et al, 2004).…”
Section: Automated Off-line Sample Preparationmentioning
confidence: 99%
“…This new technique was applied for direct analysis of model compounds in rat plasma using on-line SPE-LC-MS/MS quantification. On-line IS introduction allows for non-volumetric sample (plasma) collection and direct analysis without the need of measuring and aliquoting a fixed sample volume prior to the on-line SPE-LC-MS/MS that enables direct sample (plasma) analysis without any sample manipulation and preparation (Koal et al, 2006;Alnouti et al, 2005). On-line SPE with high flow rate (normally, 4~6 mL/min) has been achieved by using extraction columns packed with large diameter particles.…”
Section: On-line Solid-phase Extraction (Spe)mentioning
confidence: 99%
“…16 Hysphere C18 HD SPE stationary phase was chosen for sample preparation purpose, allowing higher load capacity and more uniform analyte extraction reproducibility. [24][25][26][27][28] After mobile phase desorbed analytes and Vol. 40, No.…”
Section: On-line Spe Processmentioning
confidence: 99%