2021
DOI: 10.1016/j.jaerosci.2020.105653
|View full text |Cite
|
Sign up to set email alerts
|

Determining real-time mass deposition with a quartz crystal microbalance in an electrostatic, parallel-flow, air-liquid interface exposure system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 29 publications
0
3
0
Order By: Relevance
“…Usually, the dose can be determined via quartz crystal microbalance, but in this study the deposited particle masses were found to be below the detection limits. Kaur and colleagues state the detection limit of QCM to be 50 ng/cm² [ 32 ], but the doses in this study were lower. Therefore, the applied particulate dose was determined by using the measured number concentration obtained via an ELPI by calculating the mass concentration with an assumed value for the particle density and shape.…”
Section: Methodsmentioning
confidence: 72%
“…Usually, the dose can be determined via quartz crystal microbalance, but in this study the deposited particle masses were found to be below the detection limits. Kaur and colleagues state the detection limit of QCM to be 50 ng/cm² [ 32 ], but the doses in this study were lower. Therefore, the applied particulate dose was determined by using the measured number concentration obtained via an ELPI by calculating the mass concentration with an assumed value for the particle density and shape.…”
Section: Methodsmentioning
confidence: 72%
“…28,39,40 With the ALI exposure of cells, dosimetry is typically performed using blank wells with round glass slides covering the cell growth area or full of PBS or cell media and quantified for the analytes of interest; quartz microbalances have been typically used for cigarettes. 5,[41][42][43][44][45][46][47][48] Traditionally, nicotine has been the measured analyte of choice due to its high stability, ease of measurement, and its relevance to smokers and NGP users 49,50 ; for further details, please see Table 2.…”
Section: Need To Understand the Properties Of The Equipment And To Ch...mentioning
confidence: 99%
“…Quartz crystal microbalance [41][42][43][44][45][46][47][48]51 Predictions via computational fluid dynamics (CFD) 3,52 Quick continuous measurements; excellent detection limit Not suitable for all aerosols including ENDS Carbon monoxide (CO) concentration…”
Section: Mass Deposited Surface Of Exposure Well With No Cellsmentioning
confidence: 99%