2015
DOI: 10.1002/elps.201500293
|View full text |Cite
|
Sign up to set email alerts
|

Determination of γ‐hydroxybutyric acid in saliva by capillary electrophoresis coupled with contactless conductivity and indirect UV absorbance detectors

Abstract: The aim of the current study was to optimise and validate the methodology for determination of γ-hydroxybutyric acid (GHB) in saliva by CE combined with a contactless conductivity detector (C(4)D) and indirect UV absorbance detection (λ(ABS) = 210 nm). The optimized BGE, consisting of 8.5 mM maleic acid, 17 mM arginine, 255 μM cetyltrimethylammonium bromide (CTAB), and 15% acetonitrile, was evaluated for the separation of GHB in saliva within 6 min. The performance characteristics of the CE-C(4)D-indirect UV m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 26 publications
(35 reference statements)
0
3
0
Order By: Relevance
“…Pretreatment of human body fluids prior to CE‐C 4 D analyses was performed by standard techniques, such as precipitation and liquid‐liquid extraction , moreover, the application of novel microextraction techniques was also reported. Determination of formic acid in whole blood and serum samples after methanol intoxication , three amphetamines in spiked plasma samples , plasma concentrations of branched chain amino acids in secretion studies and tamoxifen and its metabolites in plasma samples of patients with breast cancer undergoing tamoxifen treatment were presented.…”
Section: Applications Of Ce‐c4dmentioning
confidence: 99%
See 1 more Smart Citation
“…Pretreatment of human body fluids prior to CE‐C 4 D analyses was performed by standard techniques, such as precipitation and liquid‐liquid extraction , moreover, the application of novel microextraction techniques was also reported. Determination of formic acid in whole blood and serum samples after methanol intoxication , three amphetamines in spiked plasma samples , plasma concentrations of branched chain amino acids in secretion studies and tamoxifen and its metabolites in plasma samples of patients with breast cancer undergoing tamoxifen treatment were presented.…”
Section: Applications Of Ce‐c4dmentioning
confidence: 99%
“…Moreover, as the content of proteinaceous matrix components is relatively low, pretreatment of saliva samples is rather simple and usually requires dilution and filtration/centrifugation only. Various major as well as minor analytes were determined in saliva samples demonstrating the potential of CE‐C 4 D in analysis of salivary inorganic anions , γ‐hydroxybutyric acid , inorganic cations/anions and organic anions and polyamines . DOI was applied for simultaneous determination of cations and anions to reduce the total analysis time and EME (see Section ) was necessary to preconcentrate salivary polyamines to levels detectable by C 4 D .…”
Section: Applications Of Ce‐c4dmentioning
confidence: 99%
“…[6][7][8][9][10][11][12] In addition, C 4 D has the advantages of miniaturization and being nondestructive to samples. Thus it has been widely applied in the elds of environment, 13,14 food, 15,16 medicine [17][18][19] and others.…”
Section: Introductionmentioning
confidence: 99%