2012
DOI: 10.1021/ac3027838
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Water Uptake of Polymeric Ion-Selective Membranes with the Coulometric Karl Fischer and FT-IR-Attenuated Total Reflection Techniques

Abstract: The water uptake of plasticized poly(vinyl chloride) (PVC) and silicone rubber (SR) based calcium-selective membranes which are commonly used in solid-contact and coated-wire ion-selective electrodes (SC-ISEs and CWEs) was quantified with the oven based coulometric Karl Fischer (KF) technique. Two different membrane types were studied: (1) the plasticized PVC or SR (RTV 3140) membrane matrix without other added membrane components and (2) the full Ca(2+)-selective membrane formulation consisting of the membran… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
31
0
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 45 publications
(33 citation statements)
references
References 26 publications
(56 reference statements)
1
31
0
1
Order By: Relevance
“…The results confirm that the swelling measurement of the hydrogel cannot be directly associated with water uptake. The obtained results are in accordance with other studies reporting that the water uptake of plasticized poly(vinyl chloride) membranes is higher in deionized water than in 0.1 m aqueous solutions of CaCl 2 , KCl, and NaCl …”
Section: Resultssupporting
confidence: 92%
“…The results confirm that the swelling measurement of the hydrogel cannot be directly associated with water uptake. The obtained results are in accordance with other studies reporting that the water uptake of plasticized poly(vinyl chloride) membranes is higher in deionized water than in 0.1 m aqueous solutions of CaCl 2 , KCl, and NaCl …”
Section: Resultssupporting
confidence: 92%
“…We found that it is better to make the potential adjustment of the SCs before 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 Water uptake of the PPy-PFOS solid contact. The water uptake of plasticized PVC-ISMs has been recently characterized by the FTIR-ATR spectroscopy 29,30,68 and the oven based coulometric Karl Fischer titration technique. 68 It was shown that water diffuses readily through the PVC-ISMs and that the water content of the membrane is influenced by the chemical composition of the electrolyte solution contacting the ISM.…”
Section: Chemicalsmentioning
confidence: 99%
“…The water uptake of plasticized PVC-ISMs has been recently characterized by the FTIR-ATR spectroscopy 29,30,68 and the oven based coulometric Karl Fischer titration technique. 68 It was shown that water diffuses readily through the PVC-ISMs and that the water content of the membrane is influenced by the chemical composition of the electrolyte solution contacting the ISM. It was found that the water content was highest when the ISM was in contact with deionized water while the water content of the ISM decreased in 0.1 M CaCl 2 solution.…”
Section: Chemicalsmentioning
confidence: 99%
“…One of the primary causes of failure in these sensors is penetration of water through the membrane. Due to the water uptake, thin aqueous layers or pools of water can be formed at the membrane/electrode interface in potentiometric solid-contact ion sensors resulting in potential instability and poor membrane adhesion to the solid contact [3].…”
Section: Introductionmentioning