Determination of Trace Metal (Mn, Fe, Ni, Cu, Zn, Co, Cd and Pb) Concentrations in Seawater Using Single Quadrupole ICP-MS: A Comparison between Offline and Online Preconcentration Setups

Abstract: The quantification of dissolved metals in seawater requires pre-treatment before the measurement can be done, posing a risk of contamination, and requiring a time-consuming procedure. Despite the development of automated preconcentration units and sophisticated instruments, the entire process often introduces inaccuracies in quantification, especially for low-metal seawaters. This study presents a robust method for measuring dissolved metals from seawater accurately and precisely using a seaFAST and quadrupole… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
10

Relationship

3
7

Authors

Journals

citations
Cited by 16 publications
(10 citation statements)
references
References 36 publications
0
7
0
Order By: Relevance
“…Dissolved iron (dFe) concentrations were measured using a quadrupole inductively coupled plasma mass spectrometer (Agilent 7900) connected to a seaFAST S3 inline preconcentration system (Elemental Scientific) ( 101 ). The detection limit was 0.02 nM.…”
Section: Methodsmentioning
confidence: 99%
“…Dissolved iron (dFe) concentrations were measured using a quadrupole inductively coupled plasma mass spectrometer (Agilent 7900) connected to a seaFAST S3 inline preconcentration system (Elemental Scientific) ( 101 ). The detection limit was 0.02 nM.…”
Section: Methodsmentioning
confidence: 99%
“…A set of unfiltered samples was separately collected in 2015, considered as the total dissolvable fraction. Measurement of dissolved metals including dPb was performed using the established analytical setup in the TracEx laboratory, University of Stellenbosch, South Africa 62 . The analytical setup comprised a commercially available preconcentration unit (ESI® seaFAST S3) and a single quadrupole ICPMS (Agilent® Mass hunter 7900).…”
Section: Methodsmentioning
confidence: 99%
“…All samples for dFe and TaLFe were acidified to pH 1.7-1.8 with ~3 M double quartz distilled HNO3 (UP HNO3). The acidified water samples were stored (> 1 year) until analysis at Stellenbosch University (TracEx, South Africa) as described in Samanta et al 60 using online pre-concentration methods. All samples were measured in duplicate.…”
Section: Seawater Collection and Sample Analysismentioning
confidence: 99%