2005
DOI: 10.1016/j.jchromb.2005.06.017
|View full text |Cite
|
Sign up to set email alerts
|

Determination of tadalafil in small volumes of plasma by high-performance liquid chromatography with UV detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0
4

Year Published

2007
2007
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 38 publications
(22 citation statements)
references
References 10 publications
0
18
0
4
Order By: Relevance
“…The two-step extraction processes were sufficient to isolate the tadalafil and loratadine from plasma without any interfering endogenous peaks at 225 nm. The method is specific and more sensitive than the other reported methods [4,9]. No interference with constituent from the plasma matrix was observed.…”
Section: Stock Solution Stabilitymentioning
confidence: 73%
See 2 more Smart Citations
“…The two-step extraction processes were sufficient to isolate the tadalafil and loratadine from plasma without any interfering endogenous peaks at 225 nm. The method is specific and more sensitive than the other reported methods [4,9]. No interference with constituent from the plasma matrix was observed.…”
Section: Stock Solution Stabilitymentioning
confidence: 73%
“…To date, no simple, sensitive and rapid high performance liquid chromatographic method with commonly used ultraviolet absorbance detection has been reported for the tadalafil quantitation at therapeutic concentration in human plasma or serum. HPLC-UV method for determination of tadalafil in rat plasma has been reported [9]. The calibration range was 10-2000 ng/mL and the run time was 18 min.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This solution was sonicated for 10 min and centrifuged at 14,000×g for 10 min at +4°C. The supernatant was then transferred to tubes and tested for tadalafil purity by comparing its absorbance spectra with that published by Cheng and Chou (2005).…”
Section: Tadalafil Solutionmentioning
confidence: 99%
“…[4][5][6][7] Owing to these pharmacological properties, the interest in developing a new formulation of and generic tadalafil for ED treatment has increased. [8] Thus far, several chromatographic methods have been developed for tadalafil determination in plasma, including liquid chromatography (LC) coupled with ultraviolet (UV) [9,10] and fluorescence detection. [11] In recent pharmacokinetic studies, LC-tandem mass spectrometry (LC-MS/MS) has primarily been used for measuring tadalafil in plasma because of its high sensitivity and selectivity.…”
Section: Introductionmentioning
confidence: 99%