1959
DOI: 10.1021/ac60156a038
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Sulfur and Chlorine in Petroeum Liquids by X-Ray Fluorescence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0

Year Published

1960
1960
2019
2019

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(18 citation statements)
references
References 2 publications
0
17
0
Order By: Relevance
“…In the determination of manganese in gasoline, Jones (105') used an iron rod as a convenient conipensative reference to serve in place of an internal standard. In the course of a year's experience, x-ray emission spectrography as a routine method was found to give results as reliable as the ASTM methods for sulfur and chlorine in petroleum liquids (216). The much shorter time (5 minutes for each element) contributed to a marked reduction of analytical costs and to improved refinery control.…”
Section: Applications Work On Elementsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the determination of manganese in gasoline, Jones (105') used an iron rod as a convenient conipensative reference to serve in place of an internal standard. In the course of a year's experience, x-ray emission spectrography as a routine method was found to give results as reliable as the ASTM methods for sulfur and chlorine in petroleum liquids (216). The much shorter time (5 minutes for each element) contributed to a marked reduction of analytical costs and to improved refinery control.…”
Section: Applications Work On Elementsmentioning
confidence: 99%
“…113. 161 91,166) Silicon ( I S , l4, 56,68,113,198) Silver (55, 91) Strontium (3, 55, &, 159,176,219) Sulfur (SO, 61,75,113,160,161,216) Tantalum (45,100,1401 151,159,213) Tellurium (166) Thorium (22, 45,46,100,115,141,Tin (16,64,68,91,166,211) Titanium (56,64,87,100,105,151,159,195) 818)…”
Section: Slsi 'mentioning
confidence: 99%
“…If the matrix remains reasonably constant, a linear calibration equation applies. However, if the hydrogen-to-carbon ratio of the matrix varies greatly, errors of up to several per cent can result and various corrections must be applied (9,15). An internal standard method or a dilution method often can be used for the more difficult cases.…”
Section: Determination Of Sulfur Manymentioning
confidence: 99%
“…X-ray fluorescence (XRF) spectrometry analyzers are usually classified by wavelength or energy dispersion for X-ray line detection and analysis [4]. XRF spectrometry has been utilized in the laboratory for many years [5].…”
Section: Introductionmentioning
confidence: 99%