2011
DOI: 10.1016/j.fct.2011.02.025
|View full text |Cite
|
Sign up to set email alerts
|

Determination of some metal ions by flame-AAS after their preconcentration using sodium dodecyl sulfate coated alumina modified with 2-hydroxy-(3-((1-H-indol 3-yle)phenyl) methyl) 1-H-indol (2-HIYPMI)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 30 publications
(9 citation statements)
references
References 33 publications
0
9
0
Order By: Relevance
“…It is known that high concentrations of interfering ions cause matrix effects in the spectroscopic determination of metal ions in environmental and food samples (41). The influence of foreign ions such as Cd 2+ , Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , Na + , K + , Ca 2+ , Mg 2+ , and Fe 2+ on the recovery of Pb 2+ and Al 3+ was examined under optimum experimental conditions.…”
Section: Effect Of Foreign Ionsmentioning
confidence: 99%
“…It is known that high concentrations of interfering ions cause matrix effects in the spectroscopic determination of metal ions in environmental and food samples (41). The influence of foreign ions such as Cd 2+ , Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , Na + , K + , Ca 2+ , Mg 2+ , and Fe 2+ on the recovery of Pb 2+ and Al 3+ was examined under optimum experimental conditions.…”
Section: Effect Of Foreign Ionsmentioning
confidence: 99%
“…One of widely used and fast emerging preconcentrative separation techniques for this purpose is the solid-phase extraction (SPE) due to its advantages (Daniel et al 2006). So far, different SP-extractors were used for determination of Cd(II) and Zn(II) from different real samples (Rajabi et al 2014;Behbahani et al 2013Behbahani et al , 2014Barciela-Alonso et al 2014;Jamshidi et al 2011;Ghaedi et al 2013a, b, d, e;Shakerian et al 2012). An efficient solid-phase extractor should consist of a stable and insoluble porous matrix having suitable active groups that interact with heavy metal ions (Fang et al 2005).…”
Section: Introductionmentioning
confidence: 97%
“…In the viewpoint of simplicity, cleanness, low reagent, and organic consumption, SPE is most widely applied and is preferred to LLE [13]. Over the past few years, several adsorbents, such as activated carbon [14], silicagel [15], exfoliated graphite [16], carbon nanotubes [17], ion-imprinted polymers [18,19], modified organo-nanoclay [20,21], hydrogel [22], activated alumina [23], modified silica [24,25], and modified nanoalumina [26], have been used for the preconcentration of metal ions. Fe 3 O 4 nanoparticles (NPs) as an efficient class of adsorbent, are receiving increasing interest in recent years.…”
Section: Introductionmentioning