1997
DOI: 10.1016/s0003-2670(96)00572-7
|View full text |Cite
|
Sign up to set email alerts
|

Determination of small carboxylic acids by ion exclusion chromatography with electrospray mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
11
1

Year Published

1999
1999
2016
2016

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 40 publications
(13 citation statements)
references
References 22 publications
1
11
1
Order By: Relevance
“…In the IEC/ES‐MS method of Houk9 aqueous TFA was used as the mobile phase and pH adjustment of the TFA eluent was performed by post‐column addition of propanol and ammonium hydroxide to convert the carboxylic acids into anions and improve the anion signal for electrospray. Not only is this a complicated system, but the detection limits for each carboxylic acids were not always higher than our results.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the IEC/ES‐MS method of Houk9 aqueous TFA was used as the mobile phase and pH adjustment of the TFA eluent was performed by post‐column addition of propanol and ammonium hydroxide to convert the carboxylic acids into anions and improve the anion signal for electrospray. Not only is this a complicated system, but the detection limits for each carboxylic acids were not always higher than our results.…”
Section: Resultsmentioning
confidence: 99%
“…Detection limits of 10 ppm were obtained for glycolic, acetic, propionic and butyric acids. In 1997, Houk assessed the separation of a mixture of formic, glyoxylic, oxalic, 2‐hydroxyisobutyric and maleic acids, with detection limits of 2–8 ppm being obtained for ion exclusion chromatography with ESI‐MS 9. On the other hand, a recent study by Helaleh10 focused on the determination of hydrochloric, formic, acetic, propionic, isobutyric, isovaleric, valeric and isocaproic acids by ion exclusion chromatography/atmospheric pressure chemical ionization (APCI) with little sample preparation.…”
mentioning
confidence: 99%
“…This side-effect is probably one of the main analytical problems of LC-MS related techniques that may have critical consequences for the analytical results (Johnson, Houk, Feng, Johnson, & Houk, 1997;Van Eeckhaut, Lanckmans, Sarre, Smolders, & Michotte, 2009). To evaluate the matrix effect, the response of the organic acid in solution was compared with the response of these compounds in the fruit material.…”
Section: Performance Of the Lc-esi-ms Methodsmentioning
confidence: 99%
“…Currently, the main classes of organic compounds targeted by single quadrupole IC/MS are low molecular weight organic acids,1–5 carbohydrates,6, 7 and synthetic chelating agents 8–10. Important inorganic analytes are oxyhalogenides, e.g.…”
mentioning
confidence: 99%