1997
DOI: 10.1039/a701695f
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Selenomethionine in Wheat Samples: Comparison of Gas Chromatography-Microwave-induced Plasma Atomic Emission Spectrometry, Gas Chromatography-Flame Photometric Detection and Gas Chromatography–Mass Spectrometry

Abstract: Education and the Commission of the European Communities, and in particular the Standards, Measurements and Testing Programme for financial support of this work with a Marie Paper 7/01695F

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
13
0
1

Year Published

2000
2000
2023
2023

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(15 citation statements)
references
References 22 publications
1
13
0
1
Order By: Relevance
“…Quantification should be performed with the standard addition method to correct for the response from the protein digest matrix. The highest recovery of selenomethionine (84%) was obtained by carrying out the digestion with 4 M HCl at 50 °C for 50 h under nitrogen [91].…”
Section: Gas Chromatography Of Selenoamino Acidsmentioning
confidence: 96%
See 2 more Smart Citations
“…Quantification should be performed with the standard addition method to correct for the response from the protein digest matrix. The highest recovery of selenomethionine (84%) was obtained by carrying out the digestion with 4 M HCl at 50 °C for 50 h under nitrogen [91].…”
Section: Gas Chromatography Of Selenoamino Acidsmentioning
confidence: 96%
“…The most sensitive method is GC-MS, but this method is not suited for metabolites that cannot be made volatile and is handicapped when authentic standards are not available [29]. Nevertheless, a number of examples of successful quasi-direct determination of selenoamino acids in biological samples [29,91] and in selenoprotein hydrolysates [88] have been demonstrated. The technique is also valuable for the identification of alkylselenium compounds [92,93].…”
Section: Identification Of Selenium Speciesmentioning
confidence: 99%
See 1 more Smart Citation
“…A maior parte dos sistemas visa o acoplamento direto da cromatografia, em linha, a técnicas de detecção diversas, como AAS, ICP-MS [10][11][12][13][14][15][16][17][18][19][20][21] , ICP-AES 10,22-29 , AFS30, MIP 10,21,[31][32][33][34][35][36][37][38][39][40][41][42][43][44][45][46] etc. Ou seja, os diferentes equipamentos relativos a essas técnicas analíticas tornam-se os detectores, postados à saída da coluna de separação.…”
Section: Introductionunclassified
“…Calle-Guntinas et al [63] compared AED, flame photometry and GC-MS detection for selective determination of selenomethionine in wheat samples.…”
Section: Gc Microwave Plasma Atomic-emission Detection (Gc-aed)mentioning
confidence: 99%